• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7UT635.-.B...-....

7UT635.-.B...-....

Manufacturer: SIEMENS

Price: On Request

DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CONTROL KEYS, NUMBER BLOCK, CASE 1/1 X 19", 29BI, 24BO, 1 WATCHDOG CONTACT, 14I, 2IEE, SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM


Similar items in same category:
7UT6335-6EB92-1AA3 L0S 7UT6335-6EB92-1AA3 L0S DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CONTROL KEYS, NUMBER BLOCK, CASE 1/1 X 19", 21BI, 24BO, 1 WATCHDOG CONTACT, 11I, IEE, 4 VOLTAGE INPUTS (1 X 3-PHASE + 1 X 1-PHASE) CURRENT TRANSFORMER: 5A SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 176V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS485 BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURR.PROTECT.TOC PHASE (50/51): I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC 3I0 (50/51): 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC EARTH (50/51): IE>, IEE>>, IEP (INRUSH BLOCKING) WITHOUT ADDIT.VOLTAGE FUNCTIONS MULTIPLE PROTECTION FUNCTION + FREE CONFIGURABLE PROTECTION FUNCTION
7UT6335-6EB92-1BC0 L0R 7UT6335-6EB92-1BC0 L0R DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CONTROL KEYS, NUMBER BLOCK, CASE 1/1 X 19", 21BI, 24BO, 1 WATCHDOG CONTACT, 11I, IEE, 4 VOLTAGE INPUTS (1 X 3-PHASE + 1 X 1-PHASE) CURRENT TRANSFORMER: 5A SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 176V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET DOUBLE, ELECTRICAL, DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS485 BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ - 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N W/O RESISTOR AND VARISTOR) SENSITIVE OVERCURR.-TIME PROT./ TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECT. (46) BREAKER FAILURE PROTECT. (50BF) TRIP CIRCUIT SUPERVISION (74TC) ADDITIONAL FUNCTION: VOLTGAE MEASUREMENT AND OVEREXCITATION PROTECTION, OVER- /UNDERVOLTAGE PROTECTION, FREQUENCY PROTECTION, DIRECTIONAL PROTECTION, FUSE FAILURE MONITOR WITHOUT ADDITIONAL FUNCTIONS
7UT6335-6EB92-1BC1 L0S 7UT6335-6EB92-1BC1 L0S DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CONTROL KEYS, NUMBER BLOCK, CASE 1/1 X 19", 21BI, 24BO, 1 WATCHDOG CONTACT, 11I, IEE, 4 VOLTAGE INPUTS (1 X 3-PHASE + 1 X 1-PHASE) CURRENT TRANSFORMER: 5A SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 176V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS485 BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ - 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N W/O RESISTOR AND VARISTOR) SENSITIVE OVERCURR.-TIME PROT./ TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECT. (46) BREAKER FAILURE PROTECT. (50BF) TRIP CIRCUIT SUPERVISION (74TC) ADDITIONAL FUNCTION: VOLTGAE MEASUREMENT AND OVEREXCITATION PROTECTION, OVER- /UNDERVOLTAGE PROTECTION, FREQUENCY PROTECTION, DIRECTIONAL PROTECTION, FUSE FAILURE MONITOR MULTIPLE PROTECTION FUNCTION XMZ (50,51,50N/G,51N/G) REF(87N), SVS(50BF),ULS(49)
7UT635.-.....-.... 7UT635.-.....-.... DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CONTROL KEYS, NUMBER BLOCK, CASE 1/1 X 19", 29BI, 24BO, 1 WATCHDOG CONTACT, 14I, 2IEE,
7UT635.-.N...-.... 7UT635.-.N...-.... DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CONTROL KEYS, NUMBER BLOCK, CASE 1/1 X 19", 29BI, 24BO, 1 WATCHDOG CONTACT, 14I, 2IEE, SURFACE MOUNTING CASE, WITH HIGH SPEED RELAYS, SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
7UT6351-5EB01-1BA0 7UT6351-5EB01-1BA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CONTROL KEYS, NUMBER BLOCK, CASE 1/1 X 19", 29BI, 24BO, 1 WATCHDOG CONTACT, 14I, 2IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) NO SYSTEM PORT DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI4, BROWSER,ELECTRIC. RS232 BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ - 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N W/O RESISTOR AND VARISTOR) SENSITIVE OVERCURR.-TIME PROT./ TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECT. (46) BREAKER FAILURE PROTECT. (50BF) TRIP CIRCUIT SUPERVISION (74TC) WITHOUT ADDIT.VOLTAGE FUNCTIONS WITHOUT ADDITIONAL FUNCTIONS
7UT6351-5EB22-1AA3 7UT6351-5EB22-1AA3 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CONTROL KEYS, NUMBER BLOCK, CASE 1/1 X 19", 29BI, 24BO, 1 WATCHDOG CONTACT, 14I, 2IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS485, DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS485 BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURR.PROTECT.TOC PHASE (50/51): I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC 3I0 (50/51): 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC EARTH (50/51): IE>, IEE>>, IEP (INRUSH BLOCKING) WITHOUT ADDIT.VOLTAGE FUNCTIONS MULTIPLE PROTECTION FUNCTION + FREE CONFIGURABLE PROTECTION FUNCTION
7UT6351-6EB02-1AA0 7UT6351-6EB02-1AA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CONTROL KEYS, NUMBER BLOCK, CASE 1/1 X 19", 29BI, 24BO, 1 WATCHDOG CONTACT, 14I, 2IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 176V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) NO SYSTEM PORT DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS485 BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURR.PROTECT.TOC PHASE (50/51): I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC 3I0 (50/51): 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC EARTH (50/51): IE>, IEE>>, IEP (INRUSH BLOCKING) WITHOUT ADDIT.VOLTAGE FUNCTIONS WITHOUT ADDITIONAL FUNCTIONS