7UM622.-.E...-...0
Manufacturer: SIEMENS
Price: On Request
MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19", 15BI, 20BO, 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS)
Similar items in same category:
7UM6215-6EB02-0FA0 | MULTIFUNCTION MACHINE PROTECT. CASE 1/2 19", 7BI, 12BO, 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) CURRENT TRANSFORMER: 5A, IEE (SENSITIVE) SUPPLY VOLTAGE:DC 220V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 176V LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT SERVICE INTERFACE (PORT C) DIGSI/MODEM TEMPERATURE MONITORING DEVICE ELECTRICAL RS485 WITHOUT ADDIT. MEASURING FUNCT. FUNCTIONALITY: ASYNCHRONOUS MOTOR WITHOUT ADDITIONAL FUNCTIONS | |
7UM6215-6EB22-3FA0 | MULTIFUNCTION MACHINE PROTECT. CASE 1/2 19", 7BI, 12BO, 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) CURRENT TRANSFORMER: 5A, IEE (SENSITIVE) SUPPLY VOLTAGE:DC 220V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 176V LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC PROTOCOL, ELECTRIC RS 485 SERVICE INTERFACE (PORT C) DIGSI/MODEM TEMPERATURE MONITORING DEVICE ELECTRICAL RS485 METERING: PEAK VALUES, MIN/MAX-VALUES, ENERGY METERING FUNCTIONALITY: ASYNCHRONOUS MOTOR WITHOUT ADDITIONAL FUNCTIONS | |
7UM622.-.B...-...0 | MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19", 15BI, 20BO, 1 WATCHDOG CONTACT SURFACE MOUNTING CASE, TERMINALS ON THE TOP AND BOTTOM | |
7UM622.-.D...-...0 | MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19", 15BI, 20BO, 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, PLUG-IN TERMINALS (2/3POL PLUG) | |
7UM6221-4EB91-3CB0 L0E | MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19", 15BI, 20BO, 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) CURRENT TRANSFORMER: 1A, IEE (SENSITIVE) SUPPLY VOLTAGE: DC 60V TO 125V, TRIGGER LEVEL BINARY INPUT 17V LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B MODBUS, 820NM FIBER, ST-PLUG SERVICE INTERFACE (PORT C) DIGSI/MODEM ELECTRICAL RS232 METERING: PEAK VALUES, MIN/MAX-VALUES, ENERGY METERING FUNCTIONALITY: GENERATOR FULL ADDITIONAL FUNCTION: SENSITIVE ROTOR EARTH FAULT PROTECTION AND 100%-STATOR EARTH FAULT PROTECTION | |
7UM6221-5BA71-0AB0 | MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19", 15BI, 20BO, 1 WATCHDOG CONTACT SURFACE MOUNTING CASE, TERMINALS ON THE TOP AND BOTTOM CURRENT TRANSFORMER: 1A, IEE (SENSITIVE) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 73V LANGUAGE GERMAN, 50HZ, IEC, REGION DE,(LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B ANALOG OUTPUTS 2 X 0....20MA SERVICE INTERFACE (PORT C) DIGSI/MODEM ELECTRICAL RS232 WITHOUT ADDIT. MEASURING FUNCT. FUNCTIONALITY: GENERATOR BASIS ADDITIONAL FUNCTION: SENSITIVE ROTOR EARTH FAULT PROTECTION AND 100%-STATOR EARTH FAULT PROTECTION | |
7UM6221-5EB02-0AA0 | MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19", 15BI, 20BO, 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) CURRENT TRANSFORMER: 1A, IEE (SENSITIVE) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 73V LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT SERVICE INTERFACE (PORT C) DIGSI/MODEM TEMPERATURE MONITORING DEVICE ELECTRICAL RS485 WITHOUT ADDIT. MEASURING FUNCT. FUNCTIONALITY: GENERATOR BASIS WITHOUT ADDITIONAL FUNCTIONS | |
7UM6221-5EB02-0AB0 | MULTIFUNCTION MACHINE PROTECT. CASE 1/1 19", 15BI, 20BO, 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) CURRENT TRANSFORMER: 1A, IEE (SENSITIVE) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 73V LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT SERVICE INTERFACE (PORT C) DIGSI/MODEM TEMPERATURE MONITORING DEVICE ELECTRICAL RS485 WITHOUT ADDIT. MEASURING FUNCT. FUNCTIONALITY: GENERATOR BASIS ADDITIONAL FUNCTION: SENSITIVE ROTOR EARTH FAULT PROTECTION AND 100%-STATOR EARTH FAULT PROTECTION |