Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
7SK801.-.....-...0
Manufacturer: SIEMENS
Price: On Request
Motor protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BQ (2 changeover contacts) 1 live contact
Similar items in same category:
7SK725.-3A.. | SOL.-STATE OVERLD.PROTECT.RELAY 5A, 50 TO 60HZ RATED SUPPLY VOLTG.DC 110V,220V | |
7SK725.-8A.. | SOL-ST.OVERLOAD PROTECT.RELAY 5A, 50 TO 60HZ F. TRANSFORMER SUPPLY | |
7SK80.1-.... | SOL.-ST.OVERLD.PROTECT.RELAY IN CASE W. TERMINAL CONNECTION W.SHORT-CIRCUIT TRIP AND OVERLOAD TRIP W.PRECEDING LOAD FEATURE BASIC VERSION | |
7SK80.2-.... | SOL.-ST.OVERLD.PROTECT.RELAY IN CASE W. TERMINAL CONNECTION WITH SHORT-CIRCUIT TRIP AND OVERLOAD TRIP WITHOUT PRECEDING LOAD FEATURE BASIC VERSION | |
7SK8011-5EB00-1HD0 | MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT NO SYSTEM PORT NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP GROUND FAULT PROTECTION IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION LOCK OUT (86) STARTING TIME SUPERVISION (48) UNDERCURRENT MONITORING (37) RESTART INHIBIT (66/86) LOCKED ROTOR PROTECTION (14) LOAD JAM PROTECTION (51M) MOTOR STATISTICS PARAMETER CHANGEOVER MONITORING FUNCTIONS | |
7SK8011-5EB20-1HD0 | Motor protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BO (2 changeover contacts) 1 live contact Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: 60 V/ 110 V / 125 V/ 220 V DC, 115 V / 230 V AC Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) IEC60870-5-103 or DIGSI4/modem, electrical RS 485 Without system interface, Port A Measurement: fault recording Functionality: XMZ+ Overcurrent time sw. XMZ PH(50/51) I>,I>>,I>>>,Ip Ground fault protection XMZ GROUND (50N/51N: Ie>, Ie>>,Ie>>>, Iep Ground fault/Ground short circuit prot. Iee>.Iee>>,Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Motor statistics Parameter set switchover Monitoring functions | |
7SK8011-5EB26-1HD0 | Motor protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BO (2 changeover contacts) 1 live contact Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: 60 V/ 110 V / 125 V/ 220 V DC, 115 V / 230 V AC Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) IEC60870-5-103 or DIGSI4/modem, electrical RS 485 Interface, Port A (device underside, front) With Ethernet interface (DIGSI interface, thermobox connection, not IEC61850) RJ45 connector Measurement: fault recording Functionality: XMZ+ Overcurrent time sw. XMZ PH(50/51) I>,I>>,I>>>,Ip Ground fault protection XMZ GROUND (50N/51N: Ie>, Ie>>,Ie>>>, Iep Ground fault/Ground short circuit prot. Iee>.Iee>>,Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Motor statistics Parameter set switchover Monitoring functions | |
7SK8011-5EB90-1HD0 L0A | MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) PROFIBUS DP SLAVE, ELECTR.RS485 NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP GROUND FAULT PROTECTION IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION LOCK OUT (86) STARTING TIME SUPERVISION (48) UNDERCURRENT MONITORING (37) RESTART INHIBIT (66/86) LOCKED ROTOR PROTECTION (14) LOAD JAM PROTECTION (51M) MOTOR STATISTICS PARAMETER CHANGEOVER MONITORING FUNCTIONS |