7SJ802.-.....-....

7SJ802.-.....-....

Manufacturer: SIEMENS

Price: On Request

OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT


Similar items in same category:
7SJ8012-5EB90-1FA0 L0R 7SJ8012-5EB90-1FA0 L0R OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC 61850, 100MBIT ETHERNET, ELECTR., DOUBLE, RJ45 CONNECTOR NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP GROUND FAULT PROTECTION IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
7SJ8012-5EB96-1FA0 L0D 7SJ8012-5EB96-1FA0 L0D "OVERCURRENT PROTECTION RELAY HOUSING 1/6 19"", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) MODBUS, ELECTRICAL RS485 INTERFACE, PORT A (ON BOTTOM OF DEVICE) WITH ETHERNET INTERFACE (DIGSI, NOT IEC61850) RJ45 CONNECTOR METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP GROUND FAULT PROTECTION IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR"
7SJ8013-..... 7SJ8013-..... OVERCURR.TIME PROT.RELAY,3-POLE TIME SETTING 0.1 TO 8S RATED SUPPLY VOLTG.DC 110V/220V
7SJ8014-..... 7SJ8014-..... OVERCURR.TIME PROT.RELAY,3-POLE TIME SETTING 0.1 TO 8S RATED SUPPLY VOLTG.DC 125/250V
7SJ8021-5EB00-1FA0 7SJ8021-5EB00-1FA0 "OVERCURRENT PROTECTION RELAY HOUSING 1/6 19"", 4 X I, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT NO SYSTEM PORT NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP GROUND FAULT PROTECTION IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR"
7SJ8021-5EB00-1FA1 7SJ8021-5EB00-1FA1 OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT NO SYSTEM PORT NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP GROUND FAULT PROTECTION IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT WITH AUTOMATIC RECLOSING
7SJ8021-5EB06-1FA0 7SJ8021-5EB06-1FA0 OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT NO SYSTEM PORT INTERFACE, PORT A (ON BOTTOM OF DEVICE) WITH ETHERNET INTERFACE (DIGSI, NOT IEC61850) RJ45 CONNECTOR METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP GROUND FAULT PROTECTION IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
7SJ8021-5EB06-1FA1 7SJ8021-5EB06-1FA1 OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT NO SYSTEM PORT INTERFACE, PORT A (ON BOTTOM OF DEVICE) WITH ETHERNET INTERFACE (DIGSI, NOT IEC61850) RJ45 CONNECTOR METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP GROUND FAULT PROTECTION IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT WITH AUTOMATIC RECLOSING