• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7SJ6427-.....-....

7SJ6427-.....-....

Manufacturer: SIEMENS

Price: On Request

MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, CASE 1/2 19", 20BI, 8BO, 2 POWER RELAYS, (4 CONTACTS) GRAPHIC DISPLAY, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A


Similar items in same category:
7SJ64255-5EB99-1FE0 L0A+M1A 7SJ64255-5EB99-1FE0 L0A+M1A MULTIFUNCTION PROTECTIVE RELAY W.LOCAL CONTROL, SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, CASE 1/2 19", 20BI, 8BO, 2 POWER RELAYS, (4 CONTACTS) GRAPHIC DISPLAY, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS DP SLAVE, RS485 PORT C (SERVICE INTERFACE) DIGSI 4, MODEM,ELECTRICAL RS232 PORT D (ADDITIONAL INTERFACE) OPTICAL 820NM, ST-PLUG METERING: FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>,IE>>,IEP, OVERLOAD PROTECT. WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER7UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
7SJ6426-.....-.... 7SJ6426-.....-.... MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, CASE 1/2 19", 20BI, 8BO, 2 POWER RELAYS, (4 CONTACTS) GRAPHIC DISPLAY, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SENSITIVE EARTH CURRENT TRANSF.
7SJ6426-.B...-.... 7SJ6426-.B...-.... MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, CASE 1/2 19", 20BI, 8BO, 2 POWER RELAYS, (4 CONTACTS) GRAPHIC DISPLAY, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SENSITIVE EARTH CURRENT TRANSF. SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
7SJ6426-5EB22-3HF2 7SJ6426-5EB22-3HF2 MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, CASE 1/2 19", 20BI, 8BO, 2 POWER RELAYS, (4 CONTACTS) GRAPHIC DISPLAY, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SENSITIVE EARTH CURRENT TRANSF. SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC PROTOCOL, RS 485 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY:TOC+V/F MOTOR IEE +SENSITIVE DIRECT. GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE(67N): IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) PHASE ROTATION(47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) INRUSH BLOCKING, LOCK OUT (86) MOTOR PROTECT.:UNDERCURRENT(37) NEGATIVE SEQUENCE (46), START UP SUPERVISION (48) RESTART INHIBIT (66/86) UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQENCY (81O/U) FAULT LOCATOR
7SJ6427-.B...-.... 7SJ6427-.B...-.... MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, CASE 1/2 19", 20BI, 8BO, 2 POWER RELAYS, (4 CONTACTS) GRAPHIC DISPLAY, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
7SJ6451-.....-.... 7SJ6451-.....-.... MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, GRAPHIC DISPLAY, CASE 1/1 19", 33BI, 11BO, 4 POWER RELAYS, (8 CONTACTS) 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A
7SJ6451-.B...-.... 7SJ6451-.B...-.... MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, GRAPHIC DISPLAY, CASE 1/1 19", 33BI, 11BO, 4 POWER RELAYS, (8 CONTACTS) 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
7SJ6451-4EB91-1FA4 L0S 7SJ6451-4EB91-1FA4 L0S MULTIFUNCTION PROTECTIVE RELAY SYNCHRONIZATION (OPTIONAL) AND RESISTANCE TEMPERATURE DETECTOR INTERFACE, GRAPHIC DISPLAY, CASE 1/1 19", 33BI, 11BO, 4 POWER RELAYS, (8 CONTACTS) 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGG.LEVEL BINARY INPUT DC 19V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI4, RS232 METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) UNDERCURRENT MONITORING (37), DISPLACEMENT VOLTAGE (59N/64), BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86) SYNCHRONIZATION