7SJ6325-5EB22-3FE0

7SJ6325-5EB22-3FE0

Manufacturer: SIEMENS

Price: On Request

MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0.25A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) System interface Rear of the device port B IEC protocol, electrical RS 485 DIGSI 4/modem interface Rear of the device port C DIGSI 4, electrical RS 485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>,IE>>,IEP, OVERLOAD PROTECT. WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER7UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) Without automatic reclosing


Similar items in same category:
7SJ6325-4EB90-3FA0 L0S 7SJ6325-4EB90-3FA0 L0S MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0.25A) SUPPLY VOLTAGE: DC 60V TO 125V, TRIGG.LEVEL BINARY INPUT DC 19V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) WITHOUT DIGSI 4/MODEM PORT METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) UNDERCURRENT MONITORING (37), DISPLACEMENT VOLTAGE (59N/64), BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86) WITHOUT AUTO-RECLOSURE
7SJ6325-4EB90-3FE0 L0A 7SJ6325-4EB90-3FE0 L0A MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0.25A) SUPPLY VOLTAGE: DC 60V TO 125V, TRIGG.LEVEL BINARY INPUT DC 19V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS DP SLAVE, RS485 WITHOUT DIGSI 4/MODEM PORT METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>,IE>>,IEP, OVERLOAD PROTECT. WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER7UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITHOUT AUTO-RECLOSURE
7SJ6325-5EB02-3FE1 7SJ6325-5EB02-3FE1 MULTIFUNCTION PROTECTIVE RELAY BAY CONTROLLER W.LOCATED CONTR. BACKFIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0.25A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>,IE>>,IEP, OVERLOAD PROTECT. WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER7UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITH AUTOMATIC RECLOSING
7SJ6325-5EB22-3FA2 7SJ6325-5EB22-3FA2 MULTIFUNCTION PROTECTIVE RELAY BAY CONTROLLER W.LOCATED CONTR. BACKFIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0.25A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC PROTOCOL, RS 485 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) UNDERCURRENT MONITORING (37), DISPLACEMENT VOLTAGE (59N/64), BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86) FAULT LOCATOR
7SJ6325-5EB62-3FG0 7SJ6325-5EB62-3FG0 MULTIFUNCTION PROTECTIVE RELAY BAY CONTROLLER W.LOCATED CONTR. BACKFIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0.25A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS FMS SLAVE, FIBER, DOUBLE LOOP, ST-PLUG DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+ DIRECTIONAL TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PAHSE ROTATION, GROUND OVERCURRENT (50/51N): IE>, IEE>>, IEP, DIRECTIONAL TIME OVERCURRENT (67/67N WITH 50N/51N), PHASE ROTATION (47),OVERLOAD PROTECT. W.2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46) LOCK OUT (86), OVER/UNDER FREQU. (81U/O), UNDER VOLTAGE (27-1,27-2),OVER VOLTAGE (59-1) WITHOUT AUTO-RECLOSURE
7SJ6325-5EB92-3FE1 L0S 7SJ6325-5EB92-3FE1 L0S MULTIFUNCTION PROTECTIVE RELAY BAY CONTROLLER W.LOCATED CONTR. BACKFIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0.25A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>,IE>>,IEP, OVERLOAD PROTECT. WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER7UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITH AUTOMATIC RECLOSING
7SJ6325-5EB92-3HA0 L0D 7SJ6325-5EB92-3HA0 L0D MULTIFUNCTION PROTECTIVE RELAY BAY CONTROLLER W.LOCATED CONTR. BACKFIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = 5A(MIN. = 0.25A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B MODBUS, RS485 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT.(50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46) LOCK OUT (86) MOTOR PROTECTION: UNDERCURRENT (37), NEGATIVE SEQUENCE (46), START UP SUPERVERSION (48), START UP BLOCK./LOCKOUT (66/86) WITHOUT AUTO-RECLOSURE
7SJ6326-.....-.... 7SJ6326-.....-.... MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 5A, IE = SENSITIVE (MIN. = 0.001A)