7SA613.-.....-3DM6

7SA613.-.....-3DM6

Manufacturer: SIEMENS

Price: On Request

DISTANCE PROTECTION RELAY 7SA61 OPERATOR PANEL WITH: 4-LINE BACK-LIT DISPLAY, FUNCTION KEYS,NUMERICAL KEYS, PC-INTERFACE, TRIPPING 3-POLE PICKUP I>, PICKUP V</I>/ PICKUP Z<(POLYGON),V</I>/PHI AUTO-RECLOSURE, BREAKER-FAILURE PROTECTION, VOLTAGE PROTECTION, EARTH-FAULT PROT. DIRECTIONAL FOR EARTHED NETWORKS EARTH-FAULT DETECTION FOR COMPENSATED/ISOLATED NETWORKS OVERLOAD PROTECTION


Similar items in same category:
7SA613.-.....-3BM6 7SA613.-.....-3BM6 DISTANCE PROTECTION RELAY 7SA61 OPERATOR PANEL WITH: 4-LINE BACK-LIT DISPLAY, FUNCTION KEYS,NUMERICAL KEYS, PC-INTERFACE, TRIPPING 3-POLE PICKUP I>, PICKUP V</I>/ AUTO-RECLOSURE, BREAKER-FAILURE PROTECTION, VOLTAGE PROTECTION, EARTH-FAULT PROT. DIRECTIONAL FOR EARTHED NETWORKS EARTH-FAULT DETECTION FOR COMPENSATED/ISOLATED NETWORKS OVERLOAD PROTECTION
7SA613.-.....-3BM7 7SA613.-.....-3BM7 DISTANCE PROTECTION RELAY 7SA61 OPERATOR PANEL WITH: 4-LINE BACK-LIT DISPLAY, FUNCTION KEYS,NUMERICAL KEYS, PC-INTERFACE, TRIPPING 3-POLE PICKUP I>, PICKUP V</I>/ AUTO-RECLOSURE, BREAKER-FAILURE PROTECTION, VOLTAGE PROTECTION, EARTH-FAULT PROT. DIRECTIONAL FOR EARTHED NETWORKS EARTH-FAULT DETECTION FOR COMPENSATED/ISOLATED NETWORKS OVERLOAD PROTECTION MEASURED VALUES EXTENDED (MIN,MAX,MEAN)
7SA613.-.....-3DD6 7SA613.-.....-3DD6 DISTANCE PROTECTION RELAY 7SA61 OPERATOR PANEL WITH: 4-LINE BACK-LIT DISPLAY, FUNCTION KEYS,NUMERICAL KEYS, PC-INTERFACE, TRIPPING 3-POLE PICKUP I>, PICKUP V</I>/ PICKUP Z<(POLYGON),V</I>/PHI BREAKER-FAILURE PROTECTION, VOLTAGE PROTECTION, EARTH-FAULT PROT. DIRECTIONAL FOR EARTHED NETWORKS EARTH-FAULT DETECTION FOR COMPENSATED/ISOLATED NETWORKS OVERLAOD PROTECTION
7SA613.-.....-3DD7 7SA613.-.....-3DD7 DISTANCE PROTECTION RELAY 7SA61 OPERATOR PANEL WITH: 4-LINE BACK-LIT DISPLAY, FUNCTION KEYS,NUMERICAL KEYS, PC-INTERFACE, TRIPPING 3-POLE PICKUP I>, PICKUP V</I>/ PICKUP Z<(POLYGON),V</I>/PHI BREAKER-FAILURE PROTECTION, VOLTAGE PROTECTION, EARTH-FAULT PROT. DIRECTIONAL FOR EARTHED NETWORKS EARTH-FAULT DETECTION FOR COMPENSATED/ISOLATED NETWORKS OVERLAOD PROTECTION MEASURED VALUES EXTENDED (MIN,MAX,MEAN)
7SA613.-.....-3DM7 7SA613.-.....-3DM7 DISTANCE PROTECTION RELAY 7SA61 OPERATOR PANEL WITH: 4-LINE BACK-LIT DISPLAY, FUNCTION KEYS,NUMERICAL KEYS, PC-INTERFACE, TRIPPING 3-POLE PICKUP I>, PICKUP V</I>/ PICKUP Z<(POLYGON),V</I>/PHI AUTO-RECLOSURE, BREAKER-FAILURE PROTECTION, VOLTAGE PROTECTION, EARTH-FAULT PROT. DIRECTIONAL FOR EARTHED NETWORKS EARTH-FAULT DETECTION FOR COMPENSATED/ISOLATED NETWORKS OVERLOAD PROTECTION MEASURED VALUES EXTENDED (MIN,MAX,MEAN)
7SA613.-.....-3GH4 7SA613.-.....-3GH4 DISTANCE PROTECTION RELAY 7SA61 OPERATOR PANEL WITH: 4-LINE BACK-LIT DISPLAY, FUNCTION KEYS,NUMERICAL KEYS, PC-INTERFACE, TRIPPING 3-POLE PICKUP I>, PICKUP V</I>/ PICKUP Z< (POLYGON),V</I>/PHI POWER SWING DETECTION, SYNCHRO-CHECK, BREAKER-FAILURE PROTECTION, VOLTAGE PROTECTION, EARTH-FAULT PROT. DIRECTIONAL FOR EARTHED NETWORKS OVERLOAD PROTECTION
7SA613.-.....-3GH5 7SA613.-.....-3GH5 DISTANCE PROTECTION RELAY 7SA61 OPERATOR PANEL WITH: 4-LINE BACK-LIT DISPLAY, FUNCTION KEYS,NUMERICAL KEYS, PC-INTERFACE, TRIPPING 3-POLE PICKUP I>, PICKUP V</I>/ PICKUP Z< (POLYGON),V</I>/PHI POWER SWING DETECTION, SYNCHRO-CHECK, BREAKER-FAILURE PROTECTION, VOLTAGE PROTECTION, EARTH-FAULT PROT. DIRECTIONAL FOR EARTHED NETWORKS OVERLOAD PROTECTION MEASURED VALUES EXTENDED (MIN,MAX,MEAN)
7SA613.-.....-6PR4 7SA613.-.....-6PR4 DISTANCE PROTECTION RELAY 7SA61 OPERATOR PANEL WITH: 4-LINE BACK-LIT DISPLAY, FUNCTION KEYS,NUMERICAL KEYS, PC-INTERFACE, TRIPPING 3-POLE TRIPPING 1/3-POLE PICKUP I>, PICKUP V</I>/ PICKUP Z< (POLYGON),V</I>/PHI POWER SWING DETECTION, PARALLEL LINE COMPENSATION, AUTO-RECLOSURE, SYNCHRO-CHECK BREAKER-FAILURE PROTECTION, VOLTAGE PROTECTION, EARTH-FAULT PROT. DIRECTIONAL FOR EARTHED NETWORKS OVERLOAD PROTECTION