7MF4433-1EA02-2RB6-ZA02+D12
Manufacturer: SIEMENS
Price: On Request
SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: PN 160 (MWP 2320 PSI): 6 TO 600 MBAR (2.409 TO 240.9 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD EXPLOSION PROTECTION EEX IA + EEX D + DUST (ATEX) ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW WITH STAINLESS STEEL MOUNTING BRACKET DEGREE OF PROTECTION IP 68 (NOT WITH PLUG OR CABLE GLAND PG 13,5)
Similar items in same category:
7MF4433-1EA02-2NC6 | SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Silicone oil/ Measuring cell cleaning normal 6 to 600 mbar (2.4 to 240.0 in H2O) MAWP PN160 (2320 psi) Seal diaphragm: Stainless steel, Parts of the measuring cell: stainless steel Female thread 1/4-18 NPT (oval flange) Fastening thread: M10, DIN19213 Enclosure made of die-cast aluminum, process flange screws made of stainless steel International version label inscription in English (documentation on CD) Explosion protection fm + csa Cable gland 1/2-14 NPT Visible display, (setting in mA) | |
7MF4433-1EA02-2PB1 | SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 6 to 600 mbar (2.409 to 240.9 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: M10 Die-cast aluminium housing, process flange bolts stainless steel International design english inscription documentation as cd ATEX (Ex ia + Ex d) Electric connection and cable inlet: cable gland M20 x1.5 without visible digital indicator (digital display hidden, setting: mA) | |
7MF4433-1EA02-2PB6 | SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 6 to 600 mbar (2.409 to 240.9 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: M10 Die-cast aluminium housing, process flange bolts stainless steel International design english inscription documentation as cd ATEX (Ex ia + Ex d) Electric connection and cable inlet: cable gland M20 x1.5 Housing cover with window | |
7MF4433-1EA02-2RB1 | SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 6 to 600 mbar (2.409 to 240.9 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: M10 Die-cast aluminium housing, process flange bolts stainless steel International design english inscription documentation as cd ATEX (Ex ia + Ex d + Zone 1D/2D) Electric connection and cable inlet: cable gland M20 x1.5 without visible digital indicator (digital display hidden, setting: mA) | |
7MF4433-1EA22-1AB0 | SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 6 to 600 mbar (2.409 to 240.9 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: 7/16-20 unf Die-cast aluminium housing, process flange bolts stainless steel Standard design . None explosion protection Electric connection and cable inlet: cable gland M20 x1.5 without indicator | |
7MF4433-1EA22-2AC6 | SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 6 to 600 mbar (2.409 to 240.9 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: 7/16-20 unf Die-cast aluminium housing, process flange bolts stainless steel International design english inscription documentation as cd None explosion protection Electric connection and cable inlet: cable gland 1/2-14 npt Housing cover with window (setting: mA) | |
7MF4433-1EA42-1EB7-ZY01+Y21 | SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: PN 160 (MWP 2320 PSI): 6 TO 600 MBAR (2.409 TO 240.9 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 AND SIDE VENT/DRAIN DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . EX NA/IC - USE IN ZONE 2 ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW CUSTOMIZED ADJUSTMENT SUPPLEMENT Y21 REQUIRED RANGE (LINEAR CHARACTERISTIC) SPECIFY IN PLAIN TEXT: Y01:... TO ...MBAR,KPA,MPA,... ADJUSTMENT DIGITAL INDICATOR SPECIFY IN PLAIN TEXT Y21: MBAR, BAR, KPA, MPA, ... | |
7MF4433-1EA42-2EB7-ZA01+H03+Y01+Y21+C11 | SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: PN 160 (MWP 2320 PSI): 6 TO 600 MBAR (2.409 TO 240.9 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 AND SIDE VENT/DRAIN DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD EX NA/NL - USE IN ZONE 2 ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW CUSTOMIZED ADJUSTMENT SUPPLEMENT Y21 REQUIRED WITH STEEL MOUNTING BRACKET PROCESS FLANGES FOR VERTICAL IMPULSE PIPES (NOT WITH SUPPLEMENTS K01 OR K02) RANGE (LINEAR CHARACTERISTIC) SPECIFY IN PLAIN TEXT: Y01:... TO ...MBAR,KPA,MPA,... ADJUSTMENT DIGITAL INDICATOR SPECIFY IN PLAIN TEXT Y21: MBAR, BAR, KPA, MPA, ... QUALITY INSPECTION CERTIFICATE (FACTORY CALIBRATION) TO IEC 60770-2 |