7MF4433-1DB02-1AA1

7MF4433-1DB02-1AA1

Manufacturer: SIEMENS

Price: On Request

SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 2,5 to 250 mbar (1.004 to 100.4 inH2O), max. static pressure 160 bar Diaphragm hastelloy, parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: M10 Die-cast aluminium housing, process flange bolts stainless steel Standard design . None explosion protection Electric connection and cable inlet: screwed gland PG 13.5 without visible digital indicator (digital display hidden, setting: mA)


Similar items in same category:
7MF4433-1DA22-1NC6 7MF4433-1DA22-1NC6 SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 2,5 to 250 mbar (1.004 to 100.4 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: 7/16-20 unf Die-cast aluminium housing, process flange bolts stainless steel Standard design . Explosion protection fm + csa Electric connection and cable inlet: cable gland 1/2-14 npt Housing cover with window
7MF4433-1DA22-2AB0 7MF4433-1DA22-2AB0 SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 2,5 to 250 mbar (1.004 to 100.4 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: 7/16-20 unf Die-cast aluminium housing, process flange bolts stainless steel International design english inscription documentation as cd None explosion protection Electric connection and cable inlet: cable gland M20 x1.5 without indicator
7MF4433-1DA22-2AB1 7MF4433-1DA22-2AB1 SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 2,5 to 250 mbar (1.004 to 100.4 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: 7/16-20 unf Die-cast aluminium housing, process flange bolts stainless steel International design english inscription documentation as cd None explosion protection Electric connection and cable inlet: cable gland M20 x1.5 without visible digital indicator (digital display hidden, setting: mA)
7MF4433-1DA22-2BB6-ZA01 7MF4433-1DA22-2BB6-ZA01 SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: PN 160 (MWP 2320 PSI): 2,5 TO 250 MBAR (1.004 TO 100.4 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD EXPLOSION PROTECTION EEX IA ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW WITH STEEL MOUNTING BRACKET
7MF4433-1DB02-1BA6 7MF4433-1DB02-1BA6 SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: PN 160 (MWP 2320 PSI): 2,5 TO 250 MBAR (1.004 TO 100.4 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM HASTELLOY, PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . EXPLOSION PROTECTION EEX IA ELECTRIC CONNECTION AND CABLE INLET: SCREWED GLAND PG 13.5 HOUSING COVER WITH WINDOW
7MF4433-1DB22-1AA7-ZY01+Y21 7MF4433-1DB22-1AA7-ZY01+Y21 SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: PN 160 (MWP 2320 PSI): 2,5 TO 250 MBAR (1.004 TO 100.4 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM HASTELLOY, PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: SCREWED GLAND PG 13.5 HOUSING COVER WITH WINDOW CUSTOMIZED ADJUSTMENT SUPPLEMENT Y21 REQUIRED RANGE (LINEAR CHARACTERISTIC) SPECIFY IN PLAIN TEXT: Y01:... TO ...MBAR,KPA,MPA,... ADJUSTMENT DIGITAL INDICATOR SPECIFY IN PLAIN TEXT Y21: MBAR, BAR, KPA, MPA, ...
7MF4433-1DC22-1NC6 7MF4433-1DC22-1NC6 SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 2,5 to 250 mbar (1.004 to 100.4 inH2O), max. static pressure 160 bar Diaphragm hastelloy, parts of measuring cell hastelloy Process connection: 1/4-18 npt mounting thread: 7/16-20 unf Die-cast aluminium housing, process flange bolts stainless steel Standard design . Explosion protection fm + csa Electric connection and cable inlet: cable gland 1/2-14 npt Housing cover with window
7MF4433-1DY02-1AB7-ZB11+Y01+Y15+Y21+C20 7MF4433-1DY02-1AB7-ZB11+Y01+Y15+Y21+C20 SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: PN 160 (MWP 2320 PSI): 2,5 TO 250 MBAR (1.004 TO 100.4 INH2O), MAX. STATIC PRESSURE 160 BAR DESIGN FOR REMOTE SEALS. NOTE: PLEASE ADD THE DELIVERY TIME OF THE REMOTE SEAL! PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . NONE EXPLOSION PROTECTION ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW CUSTOMIZED ADJUSTMENT SUPPLEMENT Y21 REQUIRED PLATE INSCRIPTION ENGLISH RANGE (LINEAR CHARACTERISTIC) SPECIFY IN PLAIN TEXT: Y01:... TO ...MBAR,KPA,MPA,... STAINLESS STEEL TAG PLATE (MEASURING POINT DESCRIPTION) MAX.16 CHARACTER, SPECIFY IN PLAIN TEXT: ADJUSTMENT DIGITAL INDICATOR SPECIFY IN PLAIN TEXT Y21: MBAR, BAR, KPA, MPA, ... CERTIFICATE FOR USE IN SAFETY PLANTS ACC. IEC 61508 / 61511 SIL 2