7MF4034-1CC00-1AB7-ZY01+Y21

7MF4034-1CC00-1AB7-ZY01+Y21

Manufacturer: SIEMENS

Price: On Request

SITRANS P DS III PROFIBUS PA, TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEANING NOMINAL MEASURING RANGE 4 BAR G (58 PSI G), OVERLOAD LIMIT 10 BAR DIAPHRAGM HASTELLOY MEASURING CELL HASTELLOY PROCESS CONNECTION: CONNECTION SHANK G1/2 B TO EN 837-1 DIE-CAST ALUMINIUM HOUSING STANDARD DESIGN NONE EXPLOSION PROTECTION ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X 1.5 HOUSING COVER WITH WINDOW (DIGITAL INDICATOR VISIBLE, CUSTOMIZED ADJUSTMENT SUPPLEMENT Y21 REQUIRED) MEASURING RANGE TO BE SET SPECIFY IN PLAIN TEXT: Y01: ... UP TO ... MBAR, BAR, KPA, MPA, PSI ADJUSTMENT DIGITAL INDICATOR SPECIFY PLAIN TEXT Y21: MBAR, BAR, KPA, MPA,...


Similar items in same category:
7MF4033-3FA60-1BA6 7MF4033-3FA60-1BA6 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling inert measuring cell cleaning grease-free 1.6 to 160 bar g (23.2 to 2320 psi g), Overload limit 250 bar, Diaphragm stainless steel, measuring cell stainless steel Process connection: Male thread 1/2-14NPT Die-cast aluminium housing Standard design Explosion protection EEx ia Electric connection and cable inlet: screwed gland PG 13.5 Housing cover with window
7MF4034-.....-.... 7MF4034-.....-.... SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure
7MF4034-1BA10-2AB1 7MF4034-1BA10-2AB1 SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 1 bar g (14.5 psi g), overload limit 6 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing International version english inscription and documentation on cd None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 without visible digital indicator (digital display hidden, setting: mA)
7MF4034-1BY00-2AF6 7MF4034-1BY00-2AF6 SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 1 bar g (14.5 psi g), overload limit 6 bar Version for diaphragm pressure controller. Consider additional delivery time for Remote seal. Remote seals must be ordered with an additional article no. Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing International version english inscription and documentation on cd None explosion protection Electric connection and cable inlet: M12 connectors (stainless steel), (not with explosion proof, Intrinsic safety and explosion-proof) Housing cover with window
7MF4034-1DA00-1AB6 7MF4034-1DA00-1AB6 SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 16 bar g (232 psi g), overload limit 32 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window
7MF4034-1DA00-2AB1 7MF4034-1DA00-2AB1 SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 16 bar g (232 psi g), overload limit 32 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing International version english inscription and documentation on cd None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 without visible digital indicator (digital display hidden, setting: mA)
7MF4034-1DA10-1AC6 7MF4034-1DA10-1AC6 SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 16 bar g (232 psi g), overload limit 32 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland 1/2-14 npt Housing cover with window
7MF4034-1DA10-2AB1 7MF4034-1DA10-2AB1 SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 16 bar g (232 psi g), overload limit 32 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing International version english inscription and documentation on cd None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 without visible digital indicator (digital display hidden, setting: mA)