SITRANS P200 TRANSMITTERS FOR PRESSURE AND ABSOLUTE PRESSURE FOR GENERAL APPLICATIONS NON-LINEARITY: 0,25 PERCENT (TYPICALLY) WETTED PARTS MATERIAL:CERAMICS, STAINLESS STEEL PLUS SEALING MATERIAL; NON-WETTED PARTS MATERIAL: STAINLESS STEEL MEASURING RANGE FOR GAUGE: 0 TO 10 BAR, OVERLOAD- PRESSURE 25 BAR OUTPUT SIGNAL: 4 TO 20 MA TWO-WIRE CONNECTION, POWER SUPPLY DC 7 TO 33 V WITHOUT EXPLOSION PROTECTION ELECTRICAL CONNECTION: PLUG TO DIN EN 175301-803-A, THREAT FOR PACKED GLAND 1/2" - 14 NPT (WITH CONNECTOR) PROCESS CONNECTION: 1/4"-18 NPT MALE (STANDARD FOR PRESSURE RANGES PSI) SEALING MATERIAL BETWEEN SENSOR AND HOUSING: VITON (FPM, STANDARD) STANDARD VERSION
Similar items in same category:
7MF1565-3CA00-3PA4 | SITRANS P200 AESA Transmitter for gage pressure with internal FPM sealing non-linearity 0,25% (typic.) wetted parts material: ceramics, stainless steel non-wetted parts material: stainless steel Measuring range for gauge:0 to 10 bar, Overload-press. 25 bar Output signal: 4 to 20 mA two-wire connection power supply DC 7 to 33V without explosion protection Electrical connection: mounted cable, 2m connector M16; Process Connection: M20x1,5 F Special version for AESA/D | |
7MF1565-3CA00-4AA1 | SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 10 bar, Overload- pressure 25 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: Cable quick connector PG9 (not with explosion protection) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version | |
7MF1565-3CA00-4AA3 | SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 10 bar, Overload- pressure 25 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: Cable quick connector PG9 (not with explosion protection) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Special version "Made for Alfa Laval Aalborg A/S, Denmark". and Aalborg - Logo included | |
7MF1565-3CA00-5AA1 | SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 10 bar, Overload- pressure 25 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland 1/2" - 14 NPT (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version | |
7MF1565-3CA00-5GA1 | SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 10 bar, Overload- pressure 25 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland 1/2" - 14 NPT (with connector) Process connection: 1/2"-14 NPT male Sealing material between sensor and housing: Viton (FPM, Standard) Standard version | |
7MF1565-3CA00-6AA1 | SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 10 bar, Overload- pressure 25 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland PG11 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version | |
7MF1565-3CA00-6CA1 | SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 10 bar, Overload- pressure 25 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland PG11 (with connector) Process connection: G1/4" male thread to EN837-1 (1/4"-BSP male) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version | |
7MF1565-3CA01-1AA1 | SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 10 bar, Overload- pressure 25 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V with Explosion protection: EEx ia IIC T4 Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version |