• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7ME6340-4HC13-2AA1

7ME6340-4HC13-2AA1

Manufacturer: SIEMENS

Price: On Request

SITRANS F M MAG 3100 P . DN150, 6 Inch EN 1092-1, PN 16 Carbon steel flanges ASTM A 105 PTFE max 150°C (302°F) Hastelloy C Sensor for remote transmitter (order transmitter separately) No bus communication Metric Polyamid terminal box or 6000 I compact.


Similar items in same category:
7ME6340-3TC13-5AA1 7ME6340-3TC13-5AA1 SITRANS FM MAG 3100 P Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow measurement of liquids (conductive), main applications in chemical industry, process industry, pulp & paper, industrial wastewater. . DN100, 4 Inch EN 1092-1, PN 16 Carbon steel flanges ASTM A 105 PTFE max 150°C (302°F) Tantalum Sensor for remote transmitter (order transmitter separately) No bus communication Metric Polyamid terminal box or 6000 I compact.
7ME6340-3TJ13-2AA1 7ME6340-3TJ13-2AA1 SITRANS FM MAG 3100 P Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow measurement of liquids (conductive), main applications in chemical industry, process industry, pulp & paper, industrial wastewater. . DN100, 4 Inch ANSI B16.5, Class 150 Carbon steel flanges ASTM A 105 PTFE max 150°C (302°F) Hastelloy C Sensor for remote transmitter (order transmitter separately) No bus communication Metric Polyamid terminal box or 6000 I compact.
7ME6340-3TJ17-6CB2 7ME6340-3TJ17-6CB2 SITRANS F M MAG 3100 P . DN100, 4 Inch ANSI B 16.5, class 150 Carbon steel flanges ASTM A 105 PFA max 150 deg.C Hastelloy C incl. grounding electrodes (for PFA) MAG 6000 Industry std., die cast aluminium enclosure, painted 18 - 90V DC, 115 - 230V AC HART 1/2 inch NPT Polyamid Terminal or 6000 I compact.
7ME6340-4BC13-2KA1 7ME6340-4BC13-2KA1 SITRANS FM MAG 3100 P Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow measurement of liquids (conductive), main applications in chemical industry, process industry, pulp & paper, industrial wastewater. . DN125, 5 Inch EN 1092-1, PN 16 Carbon steel flanges ASTM A 105, corrosion-resistant coating of category C4 PTFE max 150°C (302°F) Hastelloy C without grounding electrodes MAG 5000, IP67 / NEMA 4X/6, Polyamid enclosure, With display, 11-30V DC/11-24V AC 50/60 Hz No bus communication Metric Polyamid terminal box or 6000 I compact.
7ME6340-4HC13-2HB1 7ME6340-4HC13-2HB1 SITRANS FM MAG 3100 P Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow measurement of liquids (conductive), main applications in chemical industry, process industry, pulp & paper, industrial wastewater. . DN150, 6 Inch EN 1092-1, PN 16 Carbon steel flanges ASTM A 105, corrosion-resistant coating of category C4 PTFE max 150°C (302°F) Hastelloy C without grounding electrodes MAG 6000, IP67 / NEMA 4X/6, Polyamid enclosure, With display, 11-30V DC/11-24V AC 50/60 Hz HART Metric cable glands, Polyamid terminal box or MAG 6000i integral mount
7ME6340-4HC13-2HE2 7ME6340-4HC13-2HE2 SITRANS FM MAG 3100 P Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow measurement of liquids (conductive), main applications in chemical industry, process industry, pulp & paper, industrial wastewater. . DN150, 6 Inch EN 1092-1, PN 16 Carbon steel flanges ASTM A 105, corrosion-resistant coating of category C4 PTFE max 150°C (302°F) Hastelloy C without grounding electrodes MAG 6000, IP67 / NEMA 4X/6, Polyamid enclosure, With display, 11-30V DC/11-24V AC 50/60 Hz MODBUS RTU/RS 485 1/2 inch NPT cable glands, Polyamid terminal box or MAG 6000i integral mount
7ME6340-4HC13-2JA1 7ME6340-4HC13-2JA1 SITRANS FM MAG 3100 P Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow measurement of liquids (conductive), main applications in chemical industry, process industry, pulp & paper, industrial wastewater. . DN150, 6 Inch EN 1092-1, PN 16 Carbon steel flanges ASTM A 105 PTFE max 150°C (302°F) Hastelloy C MAG 6000, IP67 / NEMA 4X/6, Polyamid enclosure, With display, 115-230V AC 50/60 Hz No bus communication Metric Polyamid terminal box or 6000 I compact.
7ME6340-4HC13-2KA1 7ME6340-4HC13-2KA1 SITRANS FM MAG 3100 P Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow measurement of liquids (conductive), main applications in chemical industry, process industry, pulp & paper, industrial wastewater. . DN150, 6 Inch EN 1092-1, PN 16 Carbon steel flanges ASTM A 105, corrosion-resistant coating of category C4 PTFE max 150°C (302°F) Hastelloy C without grounding electrodes MAG 5000, IP67 / NEMA 4X/6, Polyamid enclosure, With display, 11-30V DC/11-24V AC 50/60 Hz No bus communication Metric Polyamid terminal box or 6000 I compact.