• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7MB2338-2AA06-3CR1

7MB2338-2AA06-3CR1

Manufacturer: SIEMENS

Price: On Request

Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, with internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 500 vpm Max. measuring range for CO 0 to 2500 vpm Min. measuring range for NO 0 to 500 vpm Max. measuring range for NO 0 to 2500 vpm without O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: CO2 With conc. range "S" Parallel Meas. of SO2 and NO2 with UV Fotometer 3rd component to be measured Min. measuring range: 0 to 20% Max. measuring range: 0 to 100% Operator's software and documentation in English


Similar items in same category:
7MB2338-1AA06-3NF1 7MB2338-1AA06-3NF1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19-inch rack unit for installation in cabinets, sample gas connection 1/4 inch pipe, without internal sample gas pump, no separate gas paths 1st and 2nd infrared measured component CO and NO Smallest measuring range for CO: 0 to 500 vpm Largest measuring range for CO: 0 to 2500 vpm Smallest measuring range for NO: 0 to 500 vpm Largest measuring range for NO: 0 to 2500 vpm Without electrochem. O2 sensor . Auxiliary power: 230 V AC, 50 Hz 3rd measured component: SO2 3rd measured component: Smallest measuring range: 0 to 150 vpm Largest measuring range: 0 to 750 vpm Operating software, documentation English ###################################################################### With the mentioned successor device (7MB2338-1AA06-3NF1), the housing of the analyzer was slightly modified, so that the attachment of telescopic rails is no longer provided. Therefore, the accessory A31 (telescopic rails) can not be selected.
7MB2338-1AA06-3NH1 7MB2338-1AA06-3NH1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 1/4 inch tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 500 vpm Max. measuring range for CO 0 to 2500 vpm Min. measuring range for NO 0 to 500 vpm Max. measuring range for NO 0 to 2500 vpm without O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 500 vpm Max. measuring range: 0 to 2500 vpm Operator's software and documentation in English
7MB2338-1AC16-3CQ1 7MB2338-1AC16-3CQ1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 1/4 inch tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 1000 vpm Max. measuring range for CO 0 to 5000 vpm Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm with O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: CO2 With conc. range "S" Parallel Meas. of SO2 and NO2 with UV Fotometer 3rd component to be measured Min. measuring range: 0 to 10% Max. measuring range: 0 to 50% Operator's software and documentation in English
7MB2338-1AD16-3NH1 7MB2338-1AD16-3NH1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 1/4 inch tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 1 % Max. measuring range for CO 0 to 5 % Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm with O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 500 vpm Max. measuring range: 0 to 2500 vpm Operator's software and documentation in English
7MB2338-2AD00-3NJ1 7MB2338-2AD00-3NJ1 GAS ANALYZER ULTRAMAT 23 FOR MEASUREMENT OF 3 INFRARED COMPONENTS AND OXYGEN CONCENTR. 19" PLUG-IN UNIT FOR MOUNTING IN CABINETS, GAS CONNECTIONS 6 MM TUBE, WITH INTERNAL SAMPLE GAS PUMP, WITHOUT SEPARATE GAS PATHS (2 CHANNELS) 1.+ 2.COMPONENT TO BE MEASURED CO AND NO MIN. MEASURING RANGE FOR CO 0 TO 1 % MAX. MEASURING RANGE FOR CO 0 TO 5 % MIN. MEASURING RANGE FOR NO 0 TO 1000 VPM MAX. MEASURING RANGE FOR NO 0 TO 5000 VPM WITHOUT O2 SENSOR NOT USED POWER SUPPLY: AC 230 V, 50 HZ 3RD COMPONENT TO BE MEASURED: SO2 3RD COMPONENT TO BE MEASURED MIN. MEASURING RANGE: 0 TO 1000 VPM MAX. MEASURING RANGE: 0 TO 5000 VPM OPERATOR'S SOFTWARE AND DOCUMENTATION IN ENGLISH
7MB2338-2AD06-3DL1 7MB2338-2AD06-3DL1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, with internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 1 % Max. measuring range for CO 0 to 5 % Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm without O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: CH4 3rd component to be measured Min. measuring range: 0 to 0,5% Max. measuring range: 0 to 2,5% Operator's software and documentation in English
7MB2338-2AD06-3NJ1 7MB2338-2AD06-3NJ1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, with internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 1 % Max. measuring range for CO 0 to 5 % Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm without O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 1000 vpm Max. measuring range: 0 to 5000 vpm Operator's software and documentation in English
7MB2338-2AK16-6NG1 7MB2338-2AK16-6NG1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, with internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 250 mg/m3 Max. measuring range for CO 0 to 1250 mg/m3 Min. measuring range for NO 0 to 400 mg/m3 Max. measuring range for NO 0 to 2000mg/m3 with O2 sensor . Power supply: AC 230 V, 60 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 200 vpm Max. measuring range: 0 to 1000 vpm Operator's software and documentation in English