7MB2338-0AD06-3DP1

7MB2338-0AD06-3DP1

Manufacturer: SIEMENS

Price: On Request

Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 1 % Max. measuring range for CO 0 to 5 % Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm without O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: CH4 3rd component to be measured Min. measuring range: 0 to 5% Max. measuring range: 0 to 25% Operator's software and documentation in English


Similar items in same category:
7MB2338-0AA16-3NH1 7MB2338-0AA16-3NH1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 500 vpm Max. measuring range for CO 0 to 2500 vpm Min. measuring range for NO 0 to 500 vpm Max. measuring range for NO 0 to 2500 vpm with O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 500 vpm Max. measuring range: 0 to 2500 vpm Operator's software and documentation in English
7MB2338-0AB06-3NJ1 7MB2338-0AB06-3NJ1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 2000 vpm Max. measuring range for CO 0 to 10 000 vpm Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm without O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 1000 vpm Max. measuring range: 0 to 5000 vpm Operator's software and documentation in English
7MB2338-0AC16-3NH1 7MB2338-0AC16-3NH1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 1000 vpm Max. measuring range for CO 0 to 5000 vpm Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm with O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 500 vpm Max. measuring range: 0 to 2500 vpm Operator's software and documentation in English
7MB2338-0AC86-3NJ1 7MB2338-0AC86-3NJ1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 1000 vpm Max. measuring range for CO 0 to 5000 vpm Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm with paramagnetic Oxygen measuring cell . Power supply: AC 230 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 1000 vpm Max. measuring range: 0 to 5000 vpm Operator's software and documentation in English
7MB2338-0AD06-3NJ1 7MB2338-0AD06-3NJ1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 1 % Max. measuring range for CO 0 to 5 % Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm without O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 1000 vpm Max. measuring range: 0 to 5000 vpm Operator's software and documentation in English
7MB2338-0AD10-3NH1 7MB2338-0AD10-3NH1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 1 % Max. measuring range for CO 0 to 5 % Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm with O2 sensor not used Power supply: AC 230 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 500 vpm Max. measuring range: 0 to 2500 vpm Operator's software and documentation in English
7MB2338-0AD16-3DH1 7MB2338-0AD16-3DH1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 1 % Max. measuring range for CO 0 to 5 % Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm with O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: CH4 3rd component to be measured Min. measuring range: 0 to 500 vpm Max. measuring range: 0 to 2500 vpm Operator's software and documentation in English
7MB2338-0AD16-3DL1 7MB2338-0AD16-3DL1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 1 % Max. measuring range for CO 0 to 5 % Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm with O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: CH4 3rd component to be measured Min. measuring range: 0 to 0,5% Max. measuring range: 0 to 2,5% Operator's software and documentation in English