• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7MB2338-0AA16-2NH1

7MB2338-0AA16-2NH1

Manufacturer: SIEMENS

Price: On Request

Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 500 vpm Max. measuring range for CO 0 to 2500 vpm Min. measuring range for NO 0 to 500 vpm Max. measuring range for NO 0 to 2500 vpm with O2 sensor . Power supply: AC 200 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 500 vpm Max. measuring range: 0 to 2500 vpm Operator's software and documentation in English


Similar items in same category:
7MB2337-5AL16-5PH3 7MB2337-5AL16-5PH3 Ultramat 23 gas analyzer for measurement of 2 infrared Components and oxygen concentr. 19" plug-in unit for mounting in enclsoures,gas connections 1/4 inch stub, without internal sample gas pump, with seperate gas paths (2 Channels). 1st component to be measured:CO 1st component to be measured Min. measuring range: 0 to 0,5% Max. measuring range: 0 to 2,5% with O2-Sensor Without H2S-Sensor Power supply: AC 120 V, 60 Hz 2nd component to be measured: NO 2nd component to be measured Min. measuring range: 0 to 500 vpm Max. measuring range: 0 to 2500 vpm Operator's software and documentation in Spanish
7MB2337-6AR06-3CQ1 7MB2337-6AR06-3CQ1 Ultramat 23 gas analyzer for measurement of 2 infrared Components and oxygen concentr. 19" plug-in unit for mounting in enclosures,gas connections 6 mm stub,internal gas path, stainless steel (1.4571), without internal sample gas pump. 1st component to be measured:CO 1st component to be measured Min. measuring range: 0 to 20% Max. measuring range: 0 to 100% without O2-Sensor Without H2S-Sensor Power supply: AC 230 V, 50 Hz 2nd component to be measured: CO2 2nd component to be measured Min. measuring range: 0 to 10% Max. measuring range: 0 to 50% Operator's software and documentation in English
7MB2338-.....-.... 7MB2338-.....-.... Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr.
7MB2338-0AA06-3NW1 7MB2338-0AA06-3NW1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 500 vpm Max. measuring range for CO 0 to 2500 vpm Min. measuring range for NO 0 to 500 vpm Max. measuring range for NO 0 to 2500 vpm without O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 400 mg/m3 Max. measuring range: 0 to 2000 mg/m3 Operator's software and documentation in English
7MB2338-0AA16-3NH1 7MB2338-0AA16-3NH1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 500 vpm Max. measuring range for CO 0 to 2500 vpm Min. measuring range for NO 0 to 500 vpm Max. measuring range for NO 0 to 2500 vpm with O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 500 vpm Max. measuring range: 0 to 2500 vpm Operator's software and documentation in English
7MB2338-0AB06-3NJ1 7MB2338-0AB06-3NJ1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 2000 vpm Max. measuring range for CO 0 to 10 000 vpm Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm without O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 1000 vpm Max. measuring range: 0 to 5000 vpm Operator's software and documentation in English
7MB2338-0AC16-3NH1 7MB2338-0AC16-3NH1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 1000 vpm Max. measuring range for CO 0 to 5000 vpm Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm with O2 sensor . Power supply: AC 230 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 500 vpm Max. measuring range: 0 to 2500 vpm Operator's software and documentation in English
7MB2338-0AC86-3NJ1 7MB2338-0AC86-3NJ1 Gas analyzer ultramat 23 for measurement of 3 infrared Components and oxygen concentr. 19" plug-in unit for mounting in cabinets, gas connections 6 mm tube, without internal sample gas pump, without separate gas paths (2 channels) 1.+ 2.component to be measured CO and NO Min. measuring range for CO 0 to 1000 vpm Max. measuring range for CO 0 to 5000 vpm Min. measuring range for NO 0 to 1000 vpm Max. measuring range for NO 0 to 5000 vpm with paramagnetic Oxygen measuring cell . Power supply: AC 230 V, 50 Hz 3rd component to be measured: SO2 3rd component to be measured Min. measuring range: 0 to 1000 vpm Max. measuring range: 0 to 5000 vpm Operator's software and documentation in English