7MB2335-0AM16-3AA1

7MB2335-0AM16-3AA1

Manufacturer: SIEMENS

Price: On Request

Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosurrs, gas connections 6 mm stub, without internal sample gas pump. Component to be measured: CO Min. measuring range: 0 to 1% Max. measuring range: 0 to 5% with O2-Sensor Without H2S-Sensor Power supply: AC 230 V, 50 Hz . . Operator's software and documentation in english


Similar items in same category:
7MB2335-0AK86-3AA1 7MB2335-0AK86-3AA1 Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosurrs, gas connections 6 mm stub, without internal sample gas pump. Component to be measured: CO Min. measuring range: 0 to 2000 vpm Max. measuring range: 0 to 10 000 vpm with paramagnetic Oxygen measuring cell Without H2S-Sensor Power supply: AC 230 V, 50 Hz . . Operator's software and documentation in english
7MB2335-0AL06-3AA1 7MB2335-0AL06-3AA1 Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19-inch rack unit for installation in cabinets, sample gas connection 6 mm pipe, without internal sample gas pump Measured component: CO Smallest measuring range: 0 to 0.5% Largest measuring range: 0 to 2.5% Without electrochem. O2 sensor Without H2S sensor Auxiliary power: 230 V AC, 50 Hz . . Operating software, documentation English
7MB2335-0AM06-3AA1 7MB2335-0AM06-3AA1 Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosurrs, gas connections 6 mm stub, without internal sample gas pump. Component to be measured: CO Min. measuring range: 0 to 1% Max. measuring range: 0 to 5% without O2-Sensor Without H2S-Sensor Power supply: AC 230 V, 50 Hz . . Operator's software and documentation in english
7MB2335-0AM10-3AA1 7MB2335-0AM10-3AA1 ULTRAMAT 23 GAS ANALYZER FOR 1 COMPONENT AND OXYGEN MEASUREMENT (OPTION) 19" PLUG-IN UNIT FOR MOUNTING IN ENCLOSURRS, GAS CONNECTIONS 6 MM STUB, WITHOUT INTERNAL SAMPLE GAS PUMP. COMPONENT TO BE MEASURED: CO MIN. MEASURING RANGE: 0 TO 1% MAX. MEASURING RANGE: 0 TO 5% WITH O2-SENSOR WITHOUT H2S-SENSOR POWER SUPPLY: AC 230 V, 50 HZ . . OPERATOR'S SOFTWARE AND DOCUMENTATION IN ENGLISH
7MB2335-0AM16-6AA1 7MB2335-0AM16-6AA1 Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosurrs, gas connections 6 mm stub, without internal sample gas pump. Component to be measured: CO Min. measuring range: 0 to 1% Max. measuring range: 0 to 5% with O2-Sensor Without H2S-Sensor Power supply: AC 230 V, 60 Hz . . Operator's software and documentation in english
7MB2335-0AM17-3AA1 7MB2335-0AM17-3AA1 Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosurrs, gas connections 6 mm stub, without internal sample gas pump. Component to be measured: CO Min. measuring range: 0 to 1% Max. measuring range: 0 to 5% with O2-Sensor With H2S-Sensor, measuring range 0-5/50 ppm Power supply: AC 230 V, 50 Hz . . Operator's software and documentation in english
7MB2335-0AP06-3AA1 7MB2335-0AP06-3AA1 Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosurrs, gas connections 6 mm stub, without internal sample gas pump. Component to be measured: CO Min. measuring range: 0 to 5% Max. measuring range: 0 to 25% without O2-Sensor Without H2S-Sensor Power supply: AC 230 V, 50 Hz . . Operator's software and documentation in english
7MB2335-0AU06-3AA1 7MB2335-0AU06-3AA1 Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosurrs, gas connections 6 mm stub, without internal sample gas pump. Component to be measured: CO Min. measuring range: 0 to 150 mg/m3 Max. measuring range: 0 to 750 mg/m3 without O2-Sensor Without H2S-Sensor Power supply: AC 230 V, 50 Hz . . Operator's software and documentation in english