• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
6MD2213-.....-....

6MD2213-.....-....

Manufacturer: SIEMENS

Price: On Request

REMOTE TERMINAL UNIT:SICAM ERTU INCL. CUBICLE-ASSEMBLING BASED ON: S7-400 AUTOMATION SYSTEM THE SICAM ERTU ISSUES A LICENSE FOR THE REQUIRED RUN-TIME COMP: SICAM RTC FOR ERTU THESE INCLUDE THE COMPONENTS: RUN-TIME SOFTWARE FOR S7-CPU RUN-TIME SOFTWARE FOR MCP INCL. IEC 60870-5-101 (MASTER SLAVE), IEC 60870-5-104, SINAUT 8-FW, DNP V3.0 (MASTER SLAVE), TG800, IEC 60870-5-103 AND ARE INCLUDED IN THE SCOPE OF SUPPLY FOR THE USE OF MCP PROTOCOLS OR CFC SEPARATE 6MD7160* DONGLE MUST BE ORDERED 54 SLOTS (3 MODULE RACKS),


Similar items in same category:
6MD2207-.....-.AA. 6MD2207-.....-.AA. REMOTE TERMINAL UNIT:SICAM ERTU BASED ON: S7-400 AUTOMATION SYSTEM THE SICAM ERTU ISSUES A LICENSE FOR THE REQUIRED RUN-TIME COMP: SICAM RTC FOR ERTU THESE INCLUDE THE COMPONENTS: RUN-TIME SOFTWARE FOR S7-CPU RUN-TIME SOFTWARE FOR MCP INCL. IEC 60870-5-101 (MASTER SLAVE), IEC 60870-5-104, SINAUT 8-FW, DNP V3.0 (MASTER SLAVE), TG800, IEC 60870-5-103 AND ARE INCLUDED IN THE SCOPE OF SUPPLY FOR THE USE OF MCP PROTOCOLS OR CFC SEPARATE 6MD7160* DONGLE MUST BE ORDERED SUBRACK: 126 SLOTS
6MD2210-.....-.... 6MD2210-.....-.... REMOTE TERMINAL UNIT:SICAM ERTU INCL. CUBICLE-ASSEMBLING BASED ON: S7-400 AUTOMATION SYSTEM THE SICAM ERTU ISSUES A LICENSE FOR THE REQUIRED RUN-TIME COMP: SICAM RTC FOR ERTU THESE INCLUDE THE COMPONENTS: RUN-TIME SOFTWARE FOR S7-CPU RUN-TIME SOFTWARE FOR MCP INCL. IEC 60870-5-101 (MASTER SLAVE), IEC 60870-5-104, SINAUT 8-FW, DNP V3.0 (MASTER SLAVE), TG800, IEC 60870-5-103 AND ARE INCLUDED IN THE SCOPE OF SUPPLY FOR THE USE OF MCP PROTOCOLS OR CFC SEPARATE 6MD7160* DONGLE MUST BE ORDERED 9 SLOTS,
6MD2211-.....-.... 6MD2211-.....-.... REMOTE TERMINAL UNIT:SICAM ERTU INCL. CUBICLE-ASSEMBLING BASED ON: S7-400 AUTOMATION SYSTEM THE SICAM ERTU ISSUES A LICENSE FOR THE REQUIRED RUN-TIME COMP: SICAM RTC FOR ERTU THESE INCLUDE THE COMPONENTS: RUN-TIME SOFTWARE FOR S7-CPU RUN-TIME SOFTWARE FOR MCP INCL. IEC 60870-5-101 (MASTER SLAVE), IEC 60870-5-104, SINAUT 8-FW, DNP V3.0 (MASTER SLAVE), TG800, IEC 60870-5-103 AND ARE INCLUDED IN THE SCOPE OF SUPPLY FOR THE USE OF MCP PROTOCOLS OR CFC SEPARATE 6MD7160* DONGLE MUST BE ORDERED 18 SLOTS (1 MODULE RACK),
6MD2212-.....-.... 6MD2212-.....-.... REMOTE TERMINAL UNIT:SICAM ERTU INCL. CUBICLE-ASSEMBLING BASED ON: S7-400 AUTOMATION SYSTEM THE SICAM ERTU ISSUES A LICENSE FOR THE REQUIRED RUN-TIME COMP: SICAM RTC FOR ERTU THESE INCLUDE THE COMPONENTS: RUN-TIME SOFTWARE FOR S7-CPU RUN-TIME SOFTWARE FOR MCP INCL. IEC 60870-5-101 (MASTER SLAVE), IEC 60870-5-104, SINAUT 8-FW, DNP V3.0 (MASTER SLAVE), TG800, IEC 60870-5-103 AND ARE INCLUDED IN THE SCOPE OF SUPPLY FOR THE USE OF MCP PROTOCOLS OR CFC SEPARATE 6MD7160* DONGLE MUST BE ORDERED 36 SLOTS (2 MODULE RACKS),
6MD2214-.....-.... 6MD2214-.....-.... REMOTE TERMINAL UNIT:SICAM ERTU INCL. CUBICLE-ASSEMBLING BASED ON: S7-400 AUTOMATION SYSTEM THE SICAM ERTU ISSUES A LICENSE FOR THE REQUIRED RUN-TIME COMP: SICAM RTC FOR ERTU THESE INCLUDE THE COMPONENTS: RUN-TIME SOFTWARE FOR S7-CPU RUN-TIME SOFTWARE FOR MCP INCL. IEC 60870-5-101 (MASTER SLAVE), IEC 60870-5-104, SINAUT 8-FW, DNP V3.0 (MASTER SLAVE), TG800, IEC 60870-5-103 AND ARE INCLUDED IN THE SCOPE OF SUPPLY FOR THE USE OF MCP PROTOCOLS OR CFC SEPARATE 6MD7160* DONGLE MUST BE ORDERED 72 SLOTS (4 MODULE RACKS),
6MD2215-.....-.... 6MD2215-.....-.... REMOTE TERMINAL UNIT:SICAM ERTU INCL. CUBICLE-ASSEMBLING BASED ON: S7-400 AUTOMATION SYSTEM THE SICAM ERTU ISSUES A LICENSE FOR THE REQUIRED RUN-TIME COMP: SICAM RTC FOR ERTU THESE INCLUDE THE COMPONENTS: RUN-TIME SOFTWARE FOR S7-CPU RUN-TIME SOFTWARE FOR MCP INCL. IEC 60870-5-101 (MASTER SLAVE), IEC 60870-5-104, SINAUT 8-FW, DNP V3.0 (MASTER SLAVE), TG800, IEC 60870-5-103 AND ARE INCLUDED IN THE SCOPE OF SUPPLY FOR THE USE OF MCP PROTOCOLS OR CFC SEPARATE 6MD7160* DONGLE MUST BE ORDERED 90 SLOTS (5 MODULE RACKS),
6MD2300-2FA00-0AA1 6MD2300-2FA00-0AA1 3 PHASE FAULT SENSORS ADJUSTABLE FAULT CURRENT THRESHOLDS 200 A TO 1200 A AC, 1 EARTH FAULT SENSOR ADJUSTABLE FAULT CURRENT THRESHOLDS 10 A TO 100 A AC, 10% ACCURACY EACH WITH PREMOUNTED FIBER OPTICS FOR DIRECT CONNECTION TO SICAM FPI INDICATOR UNIT
6MD2300-3FA00-0AA1 6MD2300-3FA00-0AA1 3 PHASE FAULT SENSORS ADJUSTABLE FAULT CURRENT THRESHOLDS 200 A TO 800 A AC, 1 EARTH FAULT SENSOR ADJUSTABLE FAULT CURRENT THRESHOLDS 40 A TO 300 A AC, 15% ACCURACY EACH WITH PREMOUNTED FIBER OPTICS FOR DIRECT CONNECTION TO SICAM FPI INDICATOR UNIT