• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
6MD2022-.....-2AA4

6MD2022-.....-2AA4

Manufacturer: SIEMENS

Price: On Request

TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 12 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: COMPLETE PACKAGE VERSION V2.4


Similar items in same category:
6MD2022-.....-2AA0 6MD2022-.....-2AA0 FERNWIRKGERAET SICAM MINIRTU BASIS:AUTOMATISIERUNGS- SYSTEM S7-224/226 MIT TCM MODUL FUER LEITSTELLEN- ANSCHLUSS, FERNWIRK PROTOKOLL IEC 60870-5-101 UNBALANCED ANSCHLUSS VON SCHUTZGERAETEN UEBER IEC 60870-5-103, IED ANSCHLUSS UEBER MODBUS RTU PROTOKOLL, V.21-MODEM INTEGRI. MAX. 192 EINZELMELDUNGEN, ZEITSTEMPEL 10MS, MAX. 24 ZAEHLWERTE MAX. 192 EINZELBEFEHLE MAX. 36 MESSWERTE MAX. 12 ANALOGAUSGAENGE AUTOMAT.FUNKTION PROGRAMMIERBAR MESSWERTE POTENTIALGEBUNDEN KOMPLETTPAKET, VERSION V2.0
6MD2022-.....-2AA1 6MD2022-.....-2AA1 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 12 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: COMPLETE PACKAGE VERSION V2.1
6MD2022-.....-2AA2 6MD2022-.....-2AA2 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 12 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: COMPLETE PACKAGE VERSION V2.2
6MD2022-.....-2AA3 6MD2022-.....-2AA3 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 12 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: COMPLETE PACKAGE VERSION V2.3
6MD2022-.....-2AA5 6MD2022-.....-2AA5 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, SINAUT 8-FW. CONNECTION OF PROTECT.DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 12 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: COMPLETE PACKAGE VERSION V2.51
6MD2022-.....-2AA6 6MD2022-.....-2AA6 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, SINAUT 8-FW. CONNECTION OF PROTECT.DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 12 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: COMPLETE PACKAGE VERSION V2.60
6MD2022-.....-2AB4 6MD2022-.....-2AB4 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 12 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: COMPLETE PACKAGE VERSION V2.4 WITH TG800 RADIO MODE LICENSE
6MD2030-0..0.-1AA0 6MD2030-0..0.-1AA0 TELECONTROL UNIT SICAM MICRORTU BASED ON: AUTOMATION SYSTEM S7-224 OR S7-226 TELECONTROL PROTOCOL: IEC 60870-5-101,UNBALANCED MODE MAX. 16 DOUBLE-POINT INFORMAT., THEREOF 7 OR 12 MONITORED MAX. 32 SINGLE-POINT INFORMAT., THEREOF 14 OR 24 MONITORED ACQUISATION WITH 10MS SCAN MAX. 4 METERED VALUES MAX. 32 SINGLE COMMANDS, THEREOF 8 OR 10 MONITORED MAX. 16 DOUBLE-COMMANDS, THEREOF 4 OR 5 MONITORED MAX. 16 MEASURED VALUES INSULATION: 500V MEASURED VALUES NON-ISOLATED SUPPLIED IN INDIVIDUAL PARTS PROGRAM VERSION V1.00