• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
6DR5020-0NG11-0AA2

6DR5020-0NG11-0AA2

Manufacturer: SIEMENS

Price: On Request

SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA; double action; polycarbonate enclosure Standard Without explosion protection. Connection thread el.: M20x1.5 / pneu.: G 1/4 Digital I/O Module (DIO), 1 digital input, 3 digital outputs (2 min. or max. limit values, 1 fault indicator). " Analog Output Module (AOM), analog position feedback 4 ... 20 mA. Device plug M12 optionally orderable with -Z D53. Isolating power supply SITRANS I100 separately orderable (7NG4124-1AA00). . Brief instructions English / German / Chinese. Standard / Fail-Safe - Depressurizing the actuator in case of failure of electrical auxiliary power (single acting only). Manometer block aluminumG¼, double-acting with plastic manometer IP31 (MPa, bar)


Similar items in same category:
6DR5020-0NG03-0AA0 6DR5020-0NG03-0AA0 INTELLIGENT SIPART PS2 ELECTROPNEUMATIC POSITIONER FOR PNEUMATIC LINEAR AND PART-TURN ACTUATORS 2-WIRE; WITHOUT HART-INTERFACE; DOUBLE ACTION;HOUSING:MAKROLON WITH FIXABLE SLIPPING CLUTCH. WITHOUT EX-APPROVAL; CONNECTION THREAD: EL.: M20X1,5 / MEC.: G1/4 WITHOUT LIMIT MONITOR WITH BUILT-IN IY MODULE AND EMC FILTER MODULE FOR EXTERNAL POSITION SENSOR, INCL. 2ND CABLE GLAND, NOT WITH EEX D VERSION . INSTRUCTION MANUAL: GERMAN, ENGLISH . WITHOUT ATTACHED GAUGE BLOCK ASSEMBLY
6DR5020-0NG03-0AA2 6DR5020-0NG03-0AA2 SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA; double action; polycarbonate enclosure . Without explosion protection Connection thread el.: M20x1.5 / pneu.: G 1/4 Without Analog Output Module (AOM) and Analog Input Module (AIM). The internal position detection via a potentiometer is not applied but can be ordered in addition with ‑Z K11. Device plug M12 is not available. . Brief instructions German / English / Chinese Standard / Fail-Safe - Depressurizing the actuator in case of failure of electrical auxiliary power Manometer block aluminumG¼, double-acting with plastic manometer IP31 (MPa, bar)
6DR5020-0NG10-0AA0 6DR5020-0NG10-0AA0 SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA; double action; polycarbonate enclosure with fixable slipping clutch without explosion protection Connection thread el.: M20x1.5 / pneu.: G 1/4 with installed limit monitor alarm module; electronic without option module . Brief instructions German / English / Chinese . without mounted pressure gauge block
6DR5020-0NG11-0AA0 6DR5020-0NG11-0AA0 SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA; double action; polycarbonate enclosure Standard Without explosion protection. Connection thread el.: M20x1.5 / pneu.: G 1/4 Digital I/O Module (DIO), 1 digital input, 3 digital outputs (2 min. or max. limit values, 1 fault indicator). " Analog Output Module (AOM), analog position feedback 4 ... 20 mA. Device plug M12 optionally orderable with -Z D53. Isolating power supply SITRANS I100 separately orderable (7NG4124-1AA00). . Brief instructions English / German / Chinese. Standard / Fail-Safe - Depressurizing the actuator in case of failure of electrical auxiliary power (single acting only). Without Manometer block / Venting gauge block / Booster.
6DR5020-0NG13-0AA0 6DR5020-0NG13-0AA0 SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA; double action; polycarbonate enclosure . without explosion protection Connection thread el.: M20x1.5 / pneu.: G 1/4 Digital I/O Module (DIO) Optionally available with device plug M12 (D coding) Order code: -Z D55 Analog Output Module (AOM) and Analog Input Module (AIM) for external position transmitters. Internal potentiometer additionally orderable with -Z K11 . Brief instructions German / English / Chinese . without mounted pressure gauge block
6DR5020-0NG20-0AA0 6DR5020-0NG20-0AA0 SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA; double action; polycarbonate enclosure Standard Without explosion protection. Connection thread el.: M20x1.5 / pneu.: G 1/4 Inductive Limit Switches (ILS), 2 inductive limit switches and 1 digital output. " Without option module. . Brief instructions English / German / Chinese. Standard / Fail-Safe - Depressurizing the actuator in case of failure of electrical auxiliary power (single acting only). Without Manometer block / Venting gauge block / Booster.
6DR5020-0NG21-0AA0 6DR5020-0NG21-0AA0 SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA; double action; polycarbonate enclosure Standard Without explosion protection. Connection thread el.: M20x1.5 / pneu.: G 1/4 Inductive Limit Switches (ILS), 2 inductive limit switches and 1 digital output. " Analog Output Module (AOM), analog position feedback 4 ... 20 mA. Device plug M12 optionally orderable with -Z D53. Isolating power supply SITRANS I100 separately orderable (7NG4124-1AA00). . Brief instructions English / German / Chinese. Standard / Fail-Safe - Depressurizing the actuator in case of failure of electrical auxiliary power (single acting only). Without Manometer block / Venting gauge block / Booster.
6DR5020-0NG30-0AA0 6DR5020-0NG30-0AA0 SIPART PS2 smart electropneumatic positioner for pneumatic linear and part-turn actuators; 2-wire; 4...20mA; double action; polycarbonate enclosure Standard Without explosion protection. Connection thread el.: M20x1.5 / pneu.: G 1/4 Mechanic Limit Switches (MLS), 2 mechanical limit switches and 1 digital output. Not applicable for natural gas applications. Device plug M12 optionally orderable with -Z D57. Without option module. . Brief instructions English / German / Chinese. Standard / Fail-Safe - Depressurizing the actuator in case of failure of electrical auxiliary power (single acting only). Without Manometer block / Venting gauge block / Booster.