6DL2804-2AU62
Manufacturer: SIEMENS
Price: On Request
Ex-device made of stainless steel, IP65. with installation of the ET 200iSP and AirLineEx pneumatic components (these must be ordered additionally). device group II category 2 zone 1 and 2 (gas). size (WxHxD): 1000x1200x300, for max. 42 I/O modules. cable entries: 2x M32 power supply, 4x M20 bus cables and 95x M20 (7-13 mm) for signals in 5 rows, version in plastic blue. ambient operating temperature min. 0 °C The SIMATIC components to be installed in the housing must be ordered with org ID A4051007.
Similar items in same category:
6DL2804-2AE50 | Ex-device made of stainless steel, IP65. With installation of the ET 200iSP and AirLineEx pneumatic components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 110x M16 (4-9 mm) for signals in 5 rows, plastic version. Ambient operating temperature min. -20 ?C | |
6DL2804-2AE61 | Ex-device made of stainless steel, IP65. with installation of the ET 200iSP and AirLineEx pneumatic components (these must be ordered additionally). device group II category 2 zone 1 and 2 (gas). size (WxHxD): 950x450x230, for max. 25 I/O modules. cable entries: 2x M32 power supply, 4x M20 bus cables and 95x M20 (7-13 mm) for signals in 5 rows, metal version. ambient operating temperature min. 0 °C The SIMATIC components to be installed in the housing must be ordered with org ID A4051007. | |
6DL2804-2AE62 | Ex-device made of stainless steel, IP65. With installation of the ET 200iSP and AirLineEx pneumatic components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 95x M20 (6-13 mm) for signals in 5 rows, version in plastic blue. Ambient operating temperature min. -20 ?C | |
6DL2804-2AU30 | Ex-device made of stainless steel, IP65. with installation of the ET 200iSP and AirLineEx pneumatic components (these must be ordered additionally). device group II category 2 zone 1 and 2 (gas). size (WxHxD): 1000x1200x300, for max. 42 I/O modules. cable entries: 2x M32 power supply, 4x M20 bus cables and 66x M16 (4.5-9 mm) for signals in 3 rows, plastic version. ambient operating temperature min. 0 °C The SIMATIC components to be installed in the housing must be ordered with org ID A4051007. | |
6DL2804-2DD40 | Ex-device made of stainless steel, IP65. With installation of the ET 200iSP and AirLineEx pneumatic components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 36x M20 (6-13 mm) for signals in 3 rows, Version in plastic black Ambient operating temperature min. -20 ?C | |
6DL2804-2DE40 | Ex-device made of stainless steel, IP65. With installation of the ET 200iSP and AirLineEx pneumatic components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 57x M20 (6-13 mm) for signals in 3 rows, Version in plastic black Ambient operating temperature min. -20 ?C | |
6DL2804-2DE50 | Ex-device made of stainless steel, IP65. With installation of the ET 200iSP and AirLineEx pneumatic components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 110x M16 (4-9 mm) for signals in 5 rows, plastic version. Ambient operating temperature min. -20 ?C | |
6DL2804-3BD30 | Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 3 Zone 2 Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 39x M16 (4-9 mm) for signals in 3 rows, plastic version. Ambient operating temperature min. -20 ?C |