6DL2804-1DD42

6DL2804-1DD42

Manufacturer: SIEMENS

Price: On Request

Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 36x M20 (6-13 mm) for signals in 3 rows, version in plastic blue. Ambient operating temperature min. -20 ?C


Similar items in same category:
6DL2804-1AT84 6DL2804-1AT84 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). device group II category 2 zone 1 and 2 (gas). size (WxHxD): 1000x1000x300, for max. 42 I/O modules. cable entries: type and quantity according to offer. ambient operating temperature min. -20 °C The SIMATIC components to be installed in the housing must be ordered with org ID A4051007.
6DL2804-1AU84 6DL2804-1AU84 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). device group II category 2 zone 1 and 2 (gas). size (WxHxD): 1000x1200x300, for max. 42 I/O modules. cable entries: type and quantity according to offer. ambient operating temperature min. -20 °C The SIMATIC components to be installed in the housing must be ordered with org ID A4051007.
6DL2804-1DD30 6DL2804-1DD30 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 39x M16 (4-9 mm) for signals in 3 rows, plastic version. Ambient operating temperature min. -20 ?C
6DL2804-1DD32 6DL2804-1DD32 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 39x M16 (4-9 mm) for signals in 3 rows, version in plastic blue. Ambient operating temperature min. -20 ?C
6DL2804-1DD50 6DL2804-1DD50 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 65x M16 (4-9 mm) for signals in 5 rows, plastic version. Ambient operating temperature min. -20 ?C
6DL2804-1DD51 6DL2804-1DD51 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 65x M16 (4-9 mm) for signals in 5 rows, Version in metal. Ambient operating temperature min. -30 ?C (heating must be ordered separately)
6DL2804-1DD52 6DL2804-1DD52 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 65x M16 (4-9 mm) for signals in 5 rows, version in plastic blue. Ambient operating temperature min. -20 ?C
6DL2804-1DD62 6DL2804-1DD62 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 60x M20 (6-13 mm) for signals in 5 rows, version in plastic blue. Ambient operating temperature min. -20 ?C