6DL2804-1AD61

6DL2804-1AD61

Manufacturer: SIEMENS

Price: On Request

Ex-device made of stainless steel, max. IP with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 60x M20 (6-13 mm) for signals in 5 rows, version brass nickel-plated. Ambient operating temperature min. -30 ?C (heating must be ordered separately)


Similar items in same category:
6DL2804-1AD42 6DL2804-1AD42 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 36x M20 (6-13 mm) for signals in 3 rows, version in plastic blue. Ambient operating temperature min. -20 ?C
6DL2804-1AD50 6DL2804-1AD50 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 65x M16 (4-9 mm) for signals in 5 rows, plastic version. Ambient operating temperature min. -20 ?C
6DL2804-1AD51 6DL2804-1AD51 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 65x M16 (4-9 mm) for signals in 5 rows, Version in metal. Ambient operating temperature min. -30 ?C (heating must be ordered separately)
6DL2804-1AD52 6DL2804-1AD52 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 65x M16 (4-9 mm) for signals in 5 rows, version in plastic blue. Ambient operating temperature min. -20 ?C
6DL2804-1AD62 6DL2804-1AD62 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 60x M20 (6-13 mm) for signals in 5 rows, version in plastic blue. Ambient operating temperature min. -20 ?C
6DL2804-1AD84 6DL2804-1AD84 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). device group II category 2 zone 1 and 2 (gas). size (WxHxD): 650x450x230, for max. 15 I/O modules. cable entries: type and quantity according to offer. ambient operating temperature min. -20 °C The SIMATIC components to be installed in the housing must be ordered with org ID A4051007.
6DL2804-1AE30 6DL2804-1AE30 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 66x M16 (4-9 mm) for signals in 3 rows, plastic version. Ambient operating temperature min. -20 ?C
6DL2804-1AE31 6DL2804-1AE31 Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 66x M16 (4-9 mm) for signals in 3 rows, Version in metal. Ambient operating temperature min. -30 ?C (heating must be ordered separately)