Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
6DL2804-1AD41
Manufacturer: SIEMENS
Price: On Request
Ex device made of stainless steel, max. IP with installation of the ET 200iSP components (must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable entries: 2x M32 power supply, 4x M20 bus cables and 36x M20 (6-13 mm) for signals in 3 rows, brass nickel-plated version. Ambient temperature during operation min. -30 ?C (heater must be ordered separately)
Similar items in same category:
6DL2804-1AC00 | WALL-MOUNTING CASE 1050X400X230 IP 66 OF HIGH-QUALITY STEEL FOR EX-ZONE1 IN SECURETY CLASS EEX E FOR THE INSTAALATION OF UP TO 25 ET200IS-MODULS, THE ET200IS-COMPONENTS HAVE TO BE ORDERED SEPARATLY, WITH 104 M16-CONNECTIONS FOR THE I/O SIGNALS | |
6DL2804-1AD30 | Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 39x M16 (4-9 mm) for signals in 3 rows, plastic version. Ambient operating temperature min. -20 ?C | |
6DL2804-1AD31 | Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 39x M16 (4-9 mm) for signals in 3 rows, Version in metal. Ambient operating temperature min. -30 ?C (heating must be ordered separately) | |
6DL2804-1AD32 | Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 39x M16 (4-9 mm) for signals in 3 rows, version in plastic blue. Ambient operating temperature min. -20 ?C | |
6DL2804-1AD42 | Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 36x M20 (6-13 mm) for signals in 3 rows, version in plastic blue. Ambient operating temperature min. -20 ?C | |
6DL2804-1AD50 | Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 65x M16 (4-9 mm) for signals in 5 rows, plastic version. Ambient operating temperature min. -20 ?C | |
6DL2804-1AD51 | Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 65x M16 (4-9 mm) for signals in 5 rows, Version in metal. Ambient operating temperature min. -30 ?C (heating must be ordered separately) | |
6DL2804-1AD52 | Ex-device made of stainless steel, IP65. with installation of the ET 200iSP components (these must be ordered separately). Device group II Cat. 2 Zone 1 and 2 (gas). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 65x M16 (4-9 mm) for signals in 5 rows, version in plastic blue. Ambient operating temperature min. -20 ?C |