6DL2804-0DE30

6DL2804-0DE30

Manufacturer: SIEMENS

Price: On Request

Ex-device made of stainless steel, IP65. Empty enclosure prepared for installation of the ET 200iSP. Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 66x M16 (4-9 mm) for signals in 3 rows, plastic version. Ambient operating temperature -20 ?C...+70 ?C


Similar items in same category:
6DL2804-0DD42 6DL2804-0DD42 Ex-device made of stainless steel, IP65. Empty enclosure prepared for installation of the ET 200iSP. Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 36x M20 (6-13 mm) for signals in 3 rows, version in plastic blue. Ambient operating temperature -20 ?C...+70 ?C
6DL2804-0DD50 6DL2804-0DD50 Ex-device made of stainless steel, IP65. Empty enclosure prepared for installation of the ET 200iSP. Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 65x M16 (4-9 mm) for signals in 5 rows, plastic version. Ambient operating temperature -20 ?C...+70 ?C
6DL2804-0DD52 6DL2804-0DD52 Ex-device made of stainless steel, IP65. Empty enclosure prepared for installation of the ET 200iSP. Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 65x M16 (4-9 mm) for signals in 5 rows, version in plastic blue. Ambient operating temperature -20 ?C...+70 ?C
6DL2804-0DD62 6DL2804-0DD62 Ex-device made of stainless steel, IP65. Empty enclosure prepared for installation of the ET 200iSP. Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 650x450x230, for max. 15 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 60x M20 (6-13 mm) for signals in 5 rows, version in plastic blue. Ambient operating temperature -20 ?C...+70 ?C
6DL2804-0DE32 6DL2804-0DE32 Ex-device made of stainless steel, IP65. Empty enclosure prepared for installation of the ET 200iSP. Device group II Cat. 2 Zone 21 and 22 (dust). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 66x M16 (4-9 mm) for signals in 3 rows, version in plastic blue. Ambient operating temperature -20 ?C...+70 ?C
6DL2804-0DE42 6DL2804-0DE42 Ex-device made of stainless steel, IP65. Empty enclosure prepared for installation of the ET 200iSP. Device group II Zone 21 and 22 (dust). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 57x M20 (6-13 mm) for signals in 3 rows, version in plastic blue. Ambient operating temperature -20 ?C...+70 ?C
6DL2804-0DE50 6DL2804-0DE50 Ex-device made of stainless steel, IP65. Empty enclosure prepared for installation of the ET 200iSP. Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 110x M16 (4-9 mm) for signals in 5 rows, plastic version. Ambient operating temperature -20 ?C...+70 ?C
6DL2804-0DE52 6DL2804-0DE52 Ex-device made of stainless steel, IP65. Empty enclosure prepared for installation of the ET 200iSP. Device group II Cat. 3 Zone 21 and 22 (dust). Size (WxHxD): 950x450x230, for max. 25 I/O modules. Cable glands: 2x M32 power supply, 4x M20 bus cables and 110x M16 (4-9 mm) for signals in 5 rows, version in plastic blue. Ambient operating temperature -20 ?C...+70 ?C