4AV2496-0ED40-0A

4AV2496-0ED40-0A

Manufacturer: SIEMENS

Price: On Request

POWER SUPPLY; PHASES:1; PN(KW):0,24; UPRI(V):42+/-5%; USEC(V DC):24; ISEC(A DC):10/12 (60/40 CEL); F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6, EN61131-2 >UL/CSA-RECOGNIZED<>SAFETY ISOLATING TRANSFORMER<


Similar items in same category:
4AV2496-0ED00-0A 4AV2496-0ED00-0A POWER SUPPLY; PHASES:1; PN(KW):0,2; UPRI(V):100; USEC(V DC):24; ISEC(A DC):8,33; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6
4AV2496-0ED10-0A 4AV2496-0ED10-0A POWER SUPPLY; PHASES:1; PN(KW):0,24; UPRI(V):110+/-5%; USEC(V DC):24; ISEC(A DC):10; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558, EN 61131-2 >SAFETY ISOLATING TRANSFORMER<
4AV2496-0ED20-0A 4AV2496-0ED20-0A POWER SUPPLY; PHASES:1; PN(KW):0,24; UPRI(V):230+/-5%; USEC(V DC):24 DC ; 12 AC; ISEC(A DC):10ADC; 2,08AAC; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558, EN 61131
4AV2496-0ED30-0A 4AV2496-0ED30-0A POWER SUPPLY; PHASES:1; PN(KW):0,1; UPRI(V):400; USEC(V DC):24 DC; 24 AC; ISEC(A DC):4,16 DC; 10,4 AC; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; PROTECTION CL.:I; TA/ISOKL:40 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6
4AV2496-0ED50-0A 4AV2496-0ED50-0A RECTIFIER UNIT; PHASES:1; PN(KW):0,24; UPRI(V):600+/-5%; USEC(V DC):24; ISEC(A DC):10/12 (60/40 CEL); F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6, EN61131-2
4AV2496-0EE00-0A 4AV2496-0EE00-0A RECTIFIER UNIT; PHASES:1; PN(KW):0,24; UPRI(V):690+/-10%; USEC(V DC):24; ISEC(A DC):10/12 (60/40 CEL); F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6, EN61131-2 >SAFETY ISOLATING TRANSFORMER<
4AV2496-0EF00-0A 4AV2496-0EF00-0A POWER SUPPLY; PHASES:1; PN(KW):0,24; UPRI(V):400+/-10%; USEC(V DC):24; ISEC(A DC):10/12 (60/40 CEL); F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6, EN61131-2
4AV2496-3AA00-0A 4AV2496-3AA00-0A POWER SUPPLY; PHASES:1; PN(KW):0,24; UPRI(V):230-215-115-100; USEC(V DC):24; ISEC(A DC):10; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; PROTECTION CL.:I; TA/ISOKL:60 /B; W(%):5; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558; EN 61131-2/4AM48-CURUS >SAFETY ISOLATING TRANSFORMER<