4AP2742-5GA20-0FA0
Manufacturer: SIEMENS
Price: On Request
MAINS TRANSFORMER; PHASES:3; PN(KVA):2,5; UPRI(V):525+/-5%; USEC(V):400; ISEC(A):3,61; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:40; TYPE OF TERMINALS:SCREW/TAB CONNECTION /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1 >MAINS TRANSFORMER< >UL/CSA-RECOGNIZED<
Similar items in same category:
4AP2742-5FS10-2CA0 | TRANSFORMER SITAS; PHASES:3; PN/PN(S6)(KVA):2,5 /11; UPRI(V):500+/-5%; USEC(V):220; ISEC(A):6,6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YYN0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< | |
4AP2742-5FT10-2DA0 | TRANSFORMER SITAS; PHASES:3; PN/PN(S6)(KVA):2,5 /11; UPRI(V):500+/-5%; USEC(V):230; ISEC(A):6,3; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< | |
4AP2742-5FV00-2DA0 | SAFETY ISOLATING TRANSFORMER; PHASES:3; PN(KVA):2,5; UPRI(V):500+/-5%; USEC(V):42; ISEC(A):34,37; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 >UL/CSA-RECOGNIZED< >SAFETY ISOLATING TRANSFORMER< | |
4AP2742-5FX10-2AA0 | TRANSFORMER SITAS; PHASES:3; PN/PN(S6)(KVA):2,5 /11; UPRI(V):500+/-5%; USEC(V):380; ISEC(A):3,8; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< | |
4AP2742-5KT10-0FA0 | TRANSFORMER; PHASES:3; PN(KVA):2,5; UPRI(V):600+/-5%; USEC(V):230; ISEC(A):6,2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< | |
4AP2742-5LA20-2DA0 | TRANSFORMER SITAS; PHASES:3; PN/PN(S6)(KVA):2,5 /11; UPRI(V):660+/-5%; USEC(V):400; ISEC(A):3.61; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< | |
4AP2742-5MA20-2DA0 | TRANSFORMER SITAS; PHASES:3; PN/PN(S6)(KVA):2,5 /11,6; UPRI(V):690+/-5%; USEC(V):400; ISEC(A):3,6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< | |
4AP2742-5MT10-2DA0 | TRANSFORMER SITAS; PHASES:3; PN/PN(S6)(KVA):2,5 /11; UPRI(V):690+/-5%; USEC(V):230; ISEC(A):6,3; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< |