4AP2196-0FA50-2YA0

4AP2196-0FA50-2YA0

Manufacturer: SIEMENS

Price: On Request

TRANSFORMER SITAS; PHASES:3; PN/PN(S6)(KVA):1 /6,9; UPRI(V):300; USEC(V):400; ISEC(A):1,44; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YD5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER<


Similar items in same category:
4AP2196-0FA10-1XA0 4AP2196-0FA10-1XA0 AUTOTRANSFORMER; PHASES:3; PN,D(KVA):1,5; UPRI(V):480-460-440-415-400; USEC(V):230; ISEC(A):3,77; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER<
4AP2196-0FA20-2DA0 4AP2196-0FA20-2DA0 SAFETY ISOLATING TRANSFORMER; PHASES:3; PN(KVA):1; UPRI(V):690; USEC(V):24; ISEC(A):24; F(HZ):60...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 >SAFETY ISOLATING TRANSFORMER<
4AP2196-0FA30-2DA0 4AP2196-0FA30-2DA0 ISOLATION TRANSFORMER; PHASES:3; PN(KVA):1; UPRI(V):400-380-360; USEC(V):110-100-90; ISEC(A):5,2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-4 >UL/CSA-RECOGNIZED< >ISOLATION TRANSFORMER<
4AP2196-0FA40-1XA0 4AP2196-0FA40-1XA0 AUTOTRANSFORMER; PHASES:3; PN,D(KVA):5; UPRI(V):400; USEC(V):480-460-440-415; ISEC(A):6,0-6,3-6,6-7,0; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER<
4AP2196-0FA60-2XA0 4AP2196-0FA60-2XA0 AUTOTRANSFORMER; PHASES:3; PN,D(KVA):20; UPRI(V):415; USEC(V):400; ISEC(A):28,9; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YNA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER<
4AP2196-0FA70-2DA0 4AP2196-0FA70-2DA0 TRANSFORMER; PHASES:3; PN(KVA):1; UPRI(V):460+/-2,5%+/-5%; USEC(V):230; ISEC(A):2,5; F(HZ):60...60; VECTOR GR./SHIELD WNG.:DYN11 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-4 >UL/CSA-RECOGNIZED<
4AP2196-0FA80-2YA0 4AP2196-0FA80-2YA0 ISOLATION TRANSFORMER; PHASES:3; PN(KVA):1; UPRI(V):312; USEC(V):400; ISEC(A):1,44; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YD5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-4 >UL/CSA-RECOGNIZED<
4AP2196-0FB00-2DA0 4AP2196-0FB00-2DA0 TRANSFORMER SITAS; PHASES:3; PN/PN(S6)(KVA):1 /3,5; UPRI(V):400+/-2,5%+/-5%; USEC(V):400; ISEC(A):1,44; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<