4AP2196-0AH40-1XA0

4AP2196-0AH40-1XA0

Manufacturer: SIEMENS

Price: On Request

AUTOTRANSFORMER; PHASES:3; PN,D(KVA):8,52; UPRI(V) :440(SPANNUNGSTOLERANZ+/-10%); USEC(V):400; ISEC(A):12,3; F(HZ):60...60; VECTOR GR./SHIELD WNG.:YA0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-20 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER<


Similar items in same category:
4AP2196-0AG10-4AA0 4AP2196-0AG10-4AA0 SAFETY ISOLATING TRANSFORMER; PHASES:3; PN(KVA):0,639; UPRI(V):480-460-440-415-400- 380-360-240-220-200; USEC(V):49; ISEC(A):7,5; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 >UL/CSA-RECOGNIZED< >ISOLATION TRANSFORMER<
4AP2196-0AG20-2AA0 4AP2196-0AG20-2AA0 SAFETY ISOLATING TRANSFORMER; PHASES:3; PN(KVA):1; UPRI(V):400+/-5%; USEC(V):24; ISEC(A):24,1; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 >UL/CSA-RECOGNIZED< >SAFETY ISOLATING TRANSFORMER<
4AP2196-0AG30-2XA0 4AP2196-0AG30-2XA0 AUTOTRANSFORMER; PHASES:3; PN,D(KVA):2,56; UPRI(V):415-220-200; USEC(V):380-208; ISEC(A):3,9-7,1; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YNA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER<
4AP2196-0AG70-2XA0 4AP2196-0AG70-2XA0 AUTOTRANSFORMER; PHASES:3; PN,D(KVA):1,45; UPRI(V):460-230; USEC(V):400(407LEER); ISEC(A):2,1; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YA0 /0; TA/ISOKL:60 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER<
4AP2196-0AH70-2XA0 4AP2196-0AH70-2XA0 AUTOTRANSFORMER; PHASES:3; PN,D(KVA):1,3; UPRI(V):600-480-400-276-230; USEC(V):230; ISEC(A):3,2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YA0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER<
4AP2196-0AL30-0AA0 4AP2196-0AL30-0AA0 TRANSFORMER; PHASES:3; PN(KVA):1; UPRI(V):575-480-460-415-380; USEC(V):20-19-18; ISEC(A):28,9; F(HZ):60...60; VECTOR GR./SHIELD WNG.:YY0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1 >UL/CSA-RECOGNIZED<
4AP2196-0AL30-0AN2 4AP2196-0AL30-0AN2 TRANSFORMER; PHASES:3; PN(KVA):1; UPRI(V):575-480-460-415-380; USEC(V):20-19-18; ISEC(A):28,9 CONST.; F(HZ):60...60; VECTOR GR./SHIELD WNG.:YY0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1 >MAINS TRANSFORMER<
4AP2196-0AM30-4AA0 4AP2196-0AM30-4AA0 SAFETY ISOLATING TRANSFORMER; PHASES:3; PN(KVA):1; UPRI(V):400+/-5%; USEC(V):35; ISEC(A):16,5; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<