ISOLATION TRANSFORMER; PHASES:3; PN(KVA):0,5; UPRI(V):400; USEC(V):280; ISEC(A):1,03; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN11 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-4 >UL/CSA-RECOGNIZED< >ISOLATION TRANSFORMER<
Similar items in same category:
4AP2096-0FC30-2DA0 | SAFETY ISOLATING TRANSFORMER; PHASES:3; PN(KVA):0,63; UPRI(V):520; USEC(V):24; ISEC(A):15,16; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-6 >UL/CSA-RECOGNIZED<>SAFETY ISOLATING TRANSFORMER< | |
4AP2096-0FC40-2XA0 | AUTOTRANSFORMER; PHASES:3; PN,D(KVA):4,8; UPRI(V):200; USEC(V):230; ISEC(A):12,05; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YNA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER< | |
4AP2096-0FC50-2AA0 | SAFETY ISOLATING TRANSFORMER; PHASES:3; PN(KVA):0,5; UPRI(V):400; USEC(V):15; ISEC(A):19,2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 >UL/CSA-RECOGNIZED< | |
4AP2096-0FC60-2XA0 | AUTOTRANSFORMER; PHASES:3; PN,D(KVA):5,4; UPRI(V):415-400-380; USEC(V):400; ISEC(A):8; F(HZ):50...60; VECTOR GR./SHIELD WNG.:ZN0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER< | |
4AP2096-0FC80-4CA0 | CONVERTER TRANSFORMER; PHASES:3; PN(KVA):0,5; UPRI(V):400+/-2,5%; USEC(V):430; ISEC(A):0,67; UK(%):8; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YYN0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-4 >UL/CSA-RECOGNIZED< | |
4AP2096-0FD00-4CA0 | CONVERTER TRANSFORMER; PHASES:3; PN(KVA):0,5; UPRI(V):400; USEC(V):110+/-10%; ISEC(A):2,62+/-10%; UK(%):8; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YYN0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-4 >UL/CSA-RECOGNIZED< | |
4AP2096-0FD10-2XA0 | AUTOTRANSFORMER; PHASES:3; PN,D(KVA):6; UPRI(V):400; USEC(V):440; ISEC(A):7,9; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YNA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED< | |
4AP2096-0FD20-2XA0 | AUTOTRANSFORMER; PHASES:3; PN,D(KVA):6,3; UPRI(V):415+/-5%; USEC(V):400; ISEC(A):9,1; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YNA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED< |