4AP1996-0EH30-1XA0
Manufacturer: SIEMENS
Price: On Request
AUTOTRANSFORMER; PHASES:3; PN,D(KVA):0,9; UPRI(V):400+/-5%; USEC(V):230; ISEC(A):2,26; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED<
Similar items in same category:
4AP1996-0EG80-2XA0 | AUTOTRANSFORMER; PHASES:3; PN,D(KVA):4,2; UPRI(V):480 (+/-15%TOL.); USEC(V):440; ISEC(A):5,51; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YNA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER< | |
4AP1996-0EH00-2CA0 | ISOLATION TRANSFORMER; PHASES:3; PN(KVA):0,5; UPRI(V):360; USEC(V):100; ISEC(A):2,9; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YYN0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-4 >UL/CSA-RECOGNIZED< | |
4AP1996-0EH10-2CA0 | ISOLATION TRANSFORMER; PHASES:3; PN(KVA):0,42; UPRI(V):400; USEC(V):24; ISEC(A):10; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YYN0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-4 >UL/CSA-RECOGNIZED< | |
4AP1996-0EH20-2AA0 | SAFETY ISOLATING TRANSFORMER; PHASES:3; PN(KVA):0,415; UPRI(V):220; USEC(V):24; ISEC(A):10; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 >UL/CSA-RECOGNIZED< | |
4AP1996-0EH40-1XA0 | AUTOTRANSFORMER; PHASES:3; PN,D(KVA):1; UPRI(V):500+/-5%+10%+15%; USEC(V):380; ISEC(A):1,52; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER< | |
4AP1996-0EH50-2DA0 | TRANSFORMER; PHASES:3; PN(KVA):0,4; UPRI(V):140; USEC(V):400; ISEC(A):0,58; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-4 >UL/CSA-RECOGNIZED< >ISOLATION TRANSFORMER< | |
4AP1996-0EH60-2YA0 | SAFETY ISOLATING TRANSFORMER; PHASES:3; PN(KVA):0,5; UPRI(V):Y 400 / D 230; USEC(V):20-18; ISEC(A):14,4-16,0; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IIIY0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 >UL/CSA-RECOGNIZED< | |
4AP1996-0EH70-2AA0 | SAFETY ISOLATING TRANSFORMER; PHASES:3; PN(KVA):0,42; UPRI(V):690; USEC(V):19,2; ISEC(A):12,6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 >UL/CSA-RECOGNIZED< |