4AP1842-2BA20-2XA0

4AP1842-2BA20-2XA0

Manufacturer: SIEMENS

Price: On Request

AUTOTRANSFORMER; PHASES:3; PN,D(KVA):7; UPRI(V):415; USEC(V):400; ISEC(A):10,1; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YNA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER<


Similar items in same category:
4AP1842-2AB20-2XC0 4AP1842-2AB20-2XC0 AUTOTRANSFORMER; PHASES:3; PN,D(KVA):6,2; UPRI(V):400; USEC(V):415; ISEC(A):8,6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YNA0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-13
4AP1842-2AH10-2DA0 4AP1842-2AH10-2DA0 TRANSFORMER SITAS; PHASES:3; PN/PN(S6)(KVA):0,25 /0,726; UPRI(V):400; USEC(V):100; ISEC(A):1,44; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<
4AP1842-2AN00-2CA0 4AP1842-2AN00-2CA0 ISOLATION TRANSFORMER; PHASES:3; PN(KVA):0,25; UPRI(V):400; USEC(V):24; ISEC(A):6,0; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YYN0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 >UL/CSA-RECOGNIZED< >SAFETY ISOLATING TRANSFORMER<
4AP1842-2AX00-2DA0 4AP1842-2AX00-2DA0 TRANSFORMER SITAS; PHASES:3; PN/PN(S6)(KVA):0,25 /0,742; UPRI(V):400; USEC(V):48; ISEC(A):3,0; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER<
4AP1842-2CN00-2AA0 4AP1842-2CN00-2AA0 SAFETY ISOLATING TRANSFORMER; PHASES:3; PN(KVA):0,25; UPRI(V):440; USEC(V):24; ISEC(A):6,0; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YY0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6 >UL/CSA-RECOGNIZED<
4AP1842-2EA20-2DA0 4AP1842-2EA20-2DA0 TRANSFORMER SITAS; PHASES:3; PN/PN(S6)(KVA):0,25 /0,726; UPRI(V):480; USEC(V):400; ISEC(A):0,4; F(HZ):50...60; VECTOR GR./SHIELD WNG.:DYN5 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER<
4AP1842-2ET10-2XA0 4AP1842-2ET10-2XA0 AUTOTRANSFORMER; PHASES:3; PN,D(KVA):0,48; UPRI(V):480; USEC(V):230; ISEC(A):1,2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YNA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER<
4AP1842-2FA20-0AA0 4AP1842-2FA20-0AA0 ISOLATION TRANSFORMER; PHASES:3; PN(KVA):0,25; UPRI(V):500; USEC(V):400; ISEC(A):0,4; F(HZ):50...60; VECTOR GR./SHIELD WNG.:YYN0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2 >UL/CSA-RECOGNIZED<>ISOLATION TRANSFORMER<