1PS0071-1BD..-0CA3

1PS0071-1BD..-0CA3

Manufacturer: SIEMENS

Price: On Request

Low-voltage motor, Only Ex version! Squirrel-cage rotor Chemstar Loher type: ANGA-071BS-06 Converter operation Standard insulation Standard rotor Without explosion protection IP55, IC411, Size 71, IE2 6-pole 0.25 kW at 50 Hz


Similar items in same category:
1PS0071-1BD..-0BA4 1PS0071-1BD..-0BA4 Low-voltage motor, 3-ph. AC Only Ex version! Loher Chemstar platform Type: ANGA-071BS-04 VSD, standard insulation Without explosion protection IP55, IC411, Size 71, IE2 4-pole 0.37 kW at 50 Hz, DOL
1PS0071-1BD..-0BH3 1PS0071-1BD..-0BH3 Low-voltage motor, Only Ex version! Squirrel-cage rotor Chemstar Loher type: ANGA-071BT-04 Converter operation Standard insulation Standard rotor Without explosion protection IP55, IC411, Size 71, IE3 4-pole 0.37 kW at 50 Hz Deviating rating at converter
1PS0071-1BD..-0BH4 1PS0071-1BD..-0BH4 LV motor, 3-ph. AC Only Ex version! LOHER CHEMSTAR platform Type: ANGA-071BT-04 VSD, standard insulation Without explosion protection IP55, IC411, Size 071, IE3 4-pole 0.37 kW at 50 Hz, DOL
1PS0071-1BD..-0CA0 1PS0071-1BD..-0CA0 LOW-VOLTG. SQUIRREL-CAGE MOTOR LOHER TYPE: AMGA-071BH-06 STANDARD ROTOR WITHOUT EXPLOSION PROTECTION IP55, IC411, SIZE 071 06-POLE, 0,25 KW
1PS0071-1BD..-0CA4 1PS0071-1BD..-0CA4 Low-voltage motor, 3-ph. AC Only Ex version! Loher Chemstar platform Type: ANGA-071BS-06 VSD, standard insulation Without explosion protection IP55, IC411, Size 71, IE2 6-pole 0.25 kW at 50 Hz, DOL
1PS0071-1BD..-0CH3 1PS0071-1BD..-0CH3 Low-voltage motor, Only Ex version! Squirrel-cage rotor Chemstar Loher type: ANGA-071BT-06 Converter operation Standard insulation Standard rotor Without explosion protection IP55, IC411, Size 71, IE3 6-pole 0.25 kW at 50 Hz Deviating rating at converter
1PS0071-1BD..-0CH4 1PS0071-1BD..-0CH4 LV motor, 3-ph. AC Only Ex version! LOHER CHEMSTAR platform Type: ANGA-071BT-06 VSD, standard insulation Without explosion protection IP55, IC411, Size 071, IE3 6-pole 0.25 kW at 50 Hz, DOL
1PS0071-1BD..-0DA4 1PS0071-1BD..-0DA4 LV motor, 3-ph. AC Only Ex version! LOHER CHEMSTAR platform Type: ANGA-071BS-08 VSD, standard insulation Without explosion protection IP55, IC411, Size 071, IE2 8-pole 0.12 kW at 50 Hz, DOL