7SG1634-0...1-1JA0
Hersteller: SIEMENS
Preis: Auf Anfrage
OHMEGA 314 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS +DISTANCE SIGNALLING SCHEMES BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) +DIRECT TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E16 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103
Similar items in same category:
7SG1633-0...1-1JA0 | OHMEGA 311 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE MHO IMPEDANCE ZONES + DIRECTIONAL (HIGH IMPEDANCE) EARH-FAULT (67N) +DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES +CURRENT REVERSAL AND CB ECHO +SINGLE SHOT AUTO-RECLOSE WITH REACH EXTENSION SCHEME (79) +CHECK SYNCHRONISING (25) +BROKEN CODUCTOR +CIRCUIT BREAKER FAIL (50BF) NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E16 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 | |
7SG1633-0...1-1KA0 | OHMEGA 311 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE MHO IMPEDANCE ZONES + DIRECTIONAL (HIGH IMPEDANCE) EARH-FAULT (67N) +DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES +CURRENT REVERSAL AND CB ECHO +SINGLE SHOT AUTO-RECLOSE WITH REACH EXTENSION SCHEME (79) +CHECK SYNCHRONISING (25) +BROKEN CODUCTOR +CIRCUIT BREAKER FAIL (50BF) NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E16 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 | |
7SG1634-0...1-1GA0 | OHMEGA 314 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS +DISTANCE SIGNALLING SCHEMES BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) +DIRECT TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E12 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 | |
7SG1634-0...1-1HA0 | OHMEGA 314 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS +DISTANCE SIGNALLING SCHEMES BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) +DIRECT TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 | |
7SG1634-0...1-1KA0 | OHMEGA 314 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS +DISTANCE SIGNALLING SCHEMES BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) +DIRECT TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E16 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 | |
7SG1635-0...1-1GA0 | OHMEGA 315 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS + OVERCURRENT GUARD +BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) + DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E12 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 | |
7SG1635-0...1-1HA0 | OHMEGA 315 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS + OVERCURRENT GUARD +BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) + DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 | |
7SG1635-0...1-1JA0 | OHMEGA 315 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS + OVERCURRENT GUARD +BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) + DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E16 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 |